Your browser doesn't support javascript.
loading
THE IMPACT OF X-RAY UNIT TYPE USED FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURES ON PATIENT DOSES.
Tsapaki, V; Paraskeva, K D; Tsalafoutas, I A; Paspatis, G; Scotiniotis, H; Georgopoulos, P; Finou, P; Karagianis, J A.
Afiliación
  • Tsapaki V; Medical Physics Department, General Hospital 'Konstantopoulio', 3-5 Agias Olgas Str., 14233 Nea Ionia, Athens, Greece virginia@otenet.gr.
  • Paraskeva KD; Medical Physics Department, General Hospital 'Konstantopoulio', 3-5 Agias Olgas Str., 14233 Nea Ionia, Athens, Greece.
  • Tsalafoutas IA; General Anticancer Oncology Hospital 'Agios Savvas', Athens, Greece.
  • Paspatis G; General Hospital 'Venizelio', Heraklion, Crete, Greece.
  • Scotiniotis H; 'Hygeia' Hospital, Athens, Greece.
  • Georgopoulos P; General Hospital 'Nicea', Piraeus, Greece.
  • Finou P; Department of Statistics, Athens University of Economics and Business, Athens, Greece.
  • Karagianis JA; Medical Physics Department, General Hospital 'Konstantopoulio', 3-5 Agias Olgas Str., 14233 Nea Ionia, Athens, Greece.
Radiat Prot Dosimetry ; 171(4): 503-508, 2016 Dec.
Article en En | MEDLINE | ID: mdl-26582174
To investigate whether the X-ray unit type used for interventional endoscopic retrograde cholangiopancreatography (ERCP) procedures may affect patient radiation doses. A total of 471 ERCP procedures performed in 4 hospitals with 4 types of X-ray units were studied. Kerma-area product (KAP), fluoroscopy time (T) and total number of radiographs acquired (F) were recorded. KAP, T and F values exhibited a great variation, ranging from 0.1 to 130.2 Gy cm2 (mean 16 Gy cm2), 0.13 to 33.7 min (mean 5.4 min) and 0 to 26 radiographs (mean 3.5), respectively. The respective mean values for the four types of X-ray units that were investigated were as follows: KAP: 17.4, 12.5, 5.6 and 36.3 Gy cm2, T: 4.7, 5.2, 3.8 and 11.5 min and F: 1.7, 7.4, 1.9 and 4.6 radiographs. The type of the X-ray unit seems to significantly affect patient radiation dose, with the C-arm delivering the lowest and the angiography unit the highest patient doses.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Protección Radiológica / Radiografía Intervencional / Monitoreo de Radiación / Exposición Profesional / Colangiopancreatografia Retrógrada Endoscópica Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Humans Idioma: En Revista: Radiat Prot Dosimetry Año: 2016 Tipo del documento: Article País de afiliación: Grecia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Protección Radiológica / Radiografía Intervencional / Monitoreo de Radiación / Exposición Profesional / Colangiopancreatografia Retrógrada Endoscópica Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Humans Idioma: En Revista: Radiat Prot Dosimetry Año: 2016 Tipo del documento: Article País de afiliación: Grecia