Your browser doesn't support javascript.
loading
Quantification of cortisol in human eccrine sweat by liquid chromatography - tandem mass spectrometry.
Jia, Min; Chew, Wade M; Feinstein, Yelena; Skeath, Perry; Sternberg, Esther M.
Afiliación
  • Jia M; Arizona Center for Integrative Medicine, College of Medicine, the University of Arizona, Tucson, AZ 85724, USA. mjia@email.arizona.edu esternberg@email.arizona.edu.
  • Chew WM; Arizona Cancer Center, The University of Arizona, Tucson, AZ 85724, USA.
  • Feinstein Y; Center for Toxicology, College of Pharmacy, The University of Arizona, Tucson, AZ 85724, USA.
  • Skeath P; Arizona Center for Integrative Medicine, College of Medicine, the University of Arizona, Tucson, AZ 85724, USA. mjia@email.arizona.edu esternberg@email.arizona.edu.
  • Sternberg EM; Arizona Center for Integrative Medicine, College of Medicine, the University of Arizona, Tucson, AZ 85724, USA. mjia@email.arizona.edu esternberg@email.arizona.edu.
Analyst ; 141(6): 2053-60, 2016 Mar 21.
Article en En | MEDLINE | ID: mdl-26858998
ABSTRACT
Cortisol has long been recognized as the "stress biomarker" in evaluating stress related disorders. Plasma, urine or saliva are the current source for cortisol analysis. The sampling of these biofluids is either invasive or has reliability problems that could lead to inaccurate results. Sweat has drawn increasing attention as a promising source for non-invasive stress analysis. A sensitive HPLC-MS/MS method was developed for the quantitation of cortisol ((11ß)-11,17,21-trihydroxypregn-4-ene-3,20-dione) in human eccrine sweat. At least one unknown isomer that has previously not been reported and could potentially interfere with quantification was separated from cortisol with mixed mode RP HPLC. Detection of cortisol was carried out using atmospheric pressure chemical ionization (APCI) and selected reaction monitoring (SRM) in positive ion mode, using cortisol-9,11,12,12-D4 as internal standard. LOD and LOQ were estimated to be 0.04 ng ml(-1) and 0.1 ng ml(-1), respectively. Linear range of 0.10-25.00 ng ml(-1) was obtained. Intraday precision (2.5%-9.7%) and accuracy (0.5%-2.1%), interday precision (12.3%-18.7%) and accuracy (7.1%-15.1%) were achieved. This method has been successfully applied to the cortisol analysis of human eccrine sweat samples. This is the first demonstration that HPLC-MS/MS can be used for the sensitive and highly specific determination of cortisol in human eccrine sweat in the presence of at least one isomer that has similar hydrophobicity as cortisol. This study demonstrated that human eccrine sweat could be used as a promising source for non-invasive assessment of stress biomarkers such as cortisol and other steroid hormones.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sudor / Hidrocortisona / Cromatografía Líquida de Alta Presión / Pruebas de Química Clínica / Glándulas Exocrinas / Espectrometría de Masas en Tándem Límite: Humans Idioma: En Revista: Analyst Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sudor / Hidrocortisona / Cromatografía Líquida de Alta Presión / Pruebas de Química Clínica / Glándulas Exocrinas / Espectrometría de Masas en Tándem Límite: Humans Idioma: En Revista: Analyst Año: 2016 Tipo del documento: Article