Your browser doesn't support javascript.
loading
Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode.
Chandra, Sulekh; Hooda, Sunita; Tomar, Praveen Kumar; Malik, Amrita; Kumar, Ankit; Malik, Sakshi; Gautam, Seema.
Afiliación
  • Chandra S; Department of Chemistry, Zakir Husain Delhi College (University of Delhi), J. L. Nehru Marg, New Delhi 110002, India. Electronic address: schandra_00@yahoo.com.
  • Hooda S; Department of Chemistry, Acharya Narender Dev College (University of Delhi), Kalkaji, New Delhi 110019, India.
  • Tomar PK; Department of Chemistry, Zakir Husain Delhi College (University of Delhi), J. L. Nehru Marg, New Delhi 110002, India; Department of Chemistry, Acharya Narender Dev College (University of Delhi), Kalkaji, New Delhi 110019, India. Electronic address: praveen_tomar1979@yahoo.com.
  • Malik A; Department of Chemistry, Zakir Husain Delhi College (University of Delhi), J. L. Nehru Marg, New Delhi 110002, India.
  • Kumar A; Kharvel Subharti College of Pharmacy, S. V. Subharti University, Meerut, Uttar Pradesh 250005, India.
  • Malik S; Department of Chemistry, Sri Aurobindo College (University of Delhi), New Delhi 110017, India.
  • Gautam S; Department of Chemistry, Zakir Husain Delhi College (University of Delhi), J. L. Nehru Marg, New Delhi 110002, India.
Mater Sci Eng C Mater Biol Appl ; 62: 18-27, 2016 May.
Article en En | MEDLINE | ID: mdl-26952393
ABSTRACT
The PVC based-ion selective electrode viz., bis nitrato[4-hydroxyacetophenone semicarbazone] nickel(II) as an ionophore was prepared for the determination of thiocyanate ion. The ionophore was characterized by FT-IR, UV-vis, XRD, magnetic moment and elemental analysis (CHN). On the basis of spectral studies an octahedral geometry has been assigned. The best performance was obtained with a membrane composition of 31% PVC, 63% 2-nitrophenyl octylether, 4.0% ionophore and 2.0% trioctylmethyl ammonium chloride. The electrode exhibited an excellent Nernstian response to SCN(-) ion ranging from 1.0 × 10(-7) to 1.0 × 10(-1)M with a detection limit of 8.6 × 10(-8)M and a slope of -59.4 ± 0.2 mV/decade over a wide pH range (1.8-10.7) with a fast response time (6s) at 25 °C. The proposed electrode showed high selectivity for thiocyanate ion over a number of common inorganic and organic anions. It was successfully applied to direct determination of thiocyanate in biological (urine and saliva) samples in order to distinguish between smokers and non-smokers, environmental samples and as an indicator electrode for titration of thiocyanate ions with AgNO3 solution.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Potenciometría / Tiocianatos / Complejos de Coordinación / Ionóforos / Níquel Idioma: En Revista: Mater Sci Eng C Mater Biol Appl Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Potenciometría / Tiocianatos / Complejos de Coordinación / Ionóforos / Níquel Idioma: En Revista: Mater Sci Eng C Mater Biol Appl Año: 2016 Tipo del documento: Article