INTERCOMPARISON OF EYE LENS DOSEMETERS.
Behrens, R; Hupe, O; Busch, F; Denk, J; Engelhardt, J; Günther, K; Hödlmoser, H; Jordan, M; Strohmaier, J.
Afiliación
  • Behrens R; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.
  • Hupe O; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.
  • Busch F; Materialprüfungsamt Nordrhein-Westfalen (MPA), Marsbruchstraße 186, 44287 Dortmund, Germany.
  • Denk J; Helmholtz-Zentrum München (HMGU), Otto-Hahn-Ring 6, 81739 München, Germany.
  • Engelhardt J; Landesanstalt für Personendosimetrie und Strahlenschutzausbildung (LPS), Köpenicker Straße 325, 12555 Berlin, Germany.
  • Günther K; Strahlenmessstelle Berlin, Personendosismessstelle (PDMB), Rubensstr. 111, 12157 Berlin, Germany.
  • Hödlmoser H; Helmholtz-Zentrum München (HMGU), Otto-Hahn-Ring 6, 81739 München, Germany.
  • Jordan M; Materialprüfungsamt Nordrhein-Westfalen (MPA), Marsbruchstraße 186, 44287 Dortmund, Germany.
  • Strohmaier J; Karlsruher Institut für Technologie (KIT), Hermann-von Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
Radiat Prot Dosimetry ; 174(1): 6-12, 2017 Apr 20.
Article en En | MEDLINE | ID: mdl-27009241
An intercomparison of eye lens dosemeters has been conducted in terms of the quantity Hp(3). For the first time, besides photon radiation also beta radiation qualities were included. Three dosemeter types designed for the quantity Hp(3) and ten for Hp(0.07) took part in the intercomparison. As shown in a previous intercomparison for photon radiation only, the dosemeters designed for Hp(0.07) and calibrated in terms of Hp(3) performed well in photon radiation fields. But for beta radiation, it turned out that Hp(0.07) dosemeters over-responded up to a factor of 5 000 (with respect to the true Hp(3) dose) in the medium beta energy range (85Kr with a beta endpoint energy of 0.69 MeV), while some Hp(3) dosemeters performed quite well. For medium (57 keV) and high (662 keV) energy photon radiation, all dosemeter types showed response values well within the trumpet curve according to the current draft of ISO 14146.