High-power QCW microsecond-pulse solid-state sodium beacon laser with spiking suppression and D2b re-pumping.
Opt Lett ; 41(8): 1732-5, 2016 Apr 15.
Article en En | MEDLINE | ID: mdl-27082331
A 65 W quasi-continuous-wave microsecond-pulse solid-state sodium beacon laser tuned to the sodium D2a line has been developed with a linewidth of 0.3 GHz, beam quality of M2=1.38, and pulse width of 120 µs at a repetition rate of 500 Hz by sum-frequency mixing 1319 and 1064 nm diode-pumped Nd:YAG master-oscillator power-amplifier systems. The laser wavelength stability is less than ±0.15 GHz through feedback controlling. The laser spiking due to relaxation oscillations is suppressed by inserting frequency doublers in both 1319 and 1064 nm oscillators. Sodium D2b re-pumping is accomplished by tuning the frequency of the electro-optic modulator with the right D2a-D2b offset. A bright sodium laser guide star with a photon return of 1820 photons/cm2/s was achieved with the laser system when a 32 W circular polarized beam was projected to the sky during our field test at the Xinglong Observatory.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Opt Lett Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Opt Lett Año: 2016 Tipo del documento: Article