Short to Midterm Follow-Up of the Tritanium Primary Acetabular Component: A Cause for Concern.
Carli, Alberto V; Warth, Lucian C; de Mesy Bentley, Karen L; Nestor, Bryan J.
Afiliación
  • Carli AV; Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York.
  • Warth LC; Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York.
  • de Mesy Bentley KL; Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, New York.
  • Nestor BJ; Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York.
J Arthroplasty ; 32(2): 463-469, 2017 02.
Article en En | MEDLINE | ID: mdl-27642044
BACKGROUND: Several acetabular components utilizing novel ultraporous metal substrates have been introduced over the past decade. Collectively by design, they have a lower modulus of elasticity to reduce stress shielding, a higher coefficient of friction to enhance interference fit, and ultraporous surfaces to enhance osseointegration. However, little literature exists regarding their clinical performance. METHODS: This study compared the clinical and radiographic results of 109 hips in 95 patients using a Tritanium primary cup (Stryker, Mahwah, NJ) to an age, body mass index, and gender-matched cohort of 100 patients that received a contemporary cup (Stryker Trident PSL HA). RESULTS: At an average 4.24 + 1.49 years, implant survivorship of the Tritanium primary cup was 98.2%, with 2 cups revised for failure of osseointegration. One-year radiographs revealed radiolucent and radiosclerotic lines in 2 or more DeLee zones in 30.3% of cups and 3 zone involvement in 8.2%. These proportions increased (40.0% and 17.1%, respectively) at minimum 5-year follow-up. A comparison of 1 year and last follow-up radiographs revealed progression in 13.8%. Tritanium primary components with radiolucency in 2 or more zones exhibited significantly lower HHS at 2 years compared to all Trident peripheral self-locking (PSL) components (P < .0001) and Tritanium primary components with 1 zone or no radiolucency (P = .026). Scanning electron microscopy of a retrieved cup revealed local inflammatory reaction and no evidence of osseointegration. CONCLUSION: Despite adequate implant survivorship, over one third of Tritanium primary cups had 2 or more zone radiolucency at minimum 5-year follow-up with associated lower Harris hip scores.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Titanio / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Titanio / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article