Your browser doesn't support javascript.
loading
Optic Nerve Sheath Diameter on Sonography in Idiopathic Intracranial Hypertension Versus Normal.
Rehman, Hina; Khan, Muhammad Saim; Nafees, Muhammad; Rehman, Attique Ur; Habib, Asad.
Afiliación
  • Rehman H; Department of Radiology, Armed Forces Institute of Radiology and Imaging, Rawalpindi.
  • Khan MS; Department of Ophthalmology, Armed Forces Institute of Ophthalmology, Rawalpindi.
  • Nafees M; Department of Radiology, Armed Forces Institute of Radiology and Imaging, Rawalpindi.
  • Rehman AU; Department of Radiology, Armed Forces Institute of Radiology and Imaging, Rawalpindi.
  • Habib A; Department of Ophthalmology, Armed Forces Institute of Ophthalmology, Rawalpindi.
J Coll Physicians Surg Pak ; 26(9): 758-60, 2016 Sep.
Article en En | MEDLINE | ID: mdl-27671180
ABSTRACT

OBJECTIVE:

To compare the mean optic nerve sheath diameter (ONSD) in patients with idiopathic intracranial hypertension (IIH) versus normal healthy individuals using B-scan ultrasonography as diagnostic tool. STUDY

DESIGN:

Cross-sectional analytical study. PLACE AND DURATION OF STUDY Armed Forces Institute of Radiology and Imaging, Rawalpindi, Pakistan, from June to December 2015.

METHODOLOGY:

Participants aged 30 - 50 years were divided into two groups. Group A(GP) comprised of patients who were diagnosed cases of idiopathic intracranial hypertension while normal healthy adults who volunteered to participate in the study were included in Group B (GC). Ocular B mode ultrasound scan was performed on all the participants and each eye was considered separately. The optic nerve head was visualized as a linear hypoechoic structure, and ONSD was measured 3 mm behind the retina. Atotal of three readings were taken by the same radiologist and the average of three was recorded. Mean values of both groups were compared by t-test with significance at p < 0.05.

RESULTS:

Fifty-two eyes of 26 patients (26 eyes in each group) were included in the study. Twenty-four out of 26 in Group A(GP) and 23 out of 26 in Group B (GC) were females. Mean age of the patients was 33.92 ±4.89 years in group A(GP) while it was 34.69 ±4.79 years in group B (GC). Mean ONSD was 6.61 ±0.39 mm in group A(GP) and 4.33 ±0.38 mm in group B(GC) which was significantly different (p < 0.001).

CONCLUSION:

Ultrasound can provide a reliable, non-invasive tool to measure optic nerve sheath diameter in monitoring the patients with benign intracranial hypertension (BIH).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Seudotumor Cerebral / Vaina de Mielina Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: J Coll Physicians Surg Pak Asunto de la revista: MEDICINA Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Seudotumor Cerebral / Vaina de Mielina Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: J Coll Physicians Surg Pak Asunto de la revista: MEDICINA Año: 2016 Tipo del documento: Article