Your browser doesn't support javascript.
loading
Appropriate timing of blood sampling for blood gas analysis in the ventilated rabbit.
Sei, Kiguna; Fujita, Masanori; Okawa, Shinpei; Hirasawa, Takeshi; Kushibiki, Toshihiro; Sasa, Hidenori; Furuya, Kenichi; Ishihara, Miya.
Afiliación
  • Sei K; Department of Obstetrics and Gynecology, National Defense Medical College, Tokorozawa, Saitama, Japan. Electronic address: sei@ndmc.ac.jp.
  • Fujita M; Division of Environmental Medicine, National Defense Medical College Research Institute, Tokorozawa, Saitama, Japan. Electronic address: fujitama@ndmc.ac.jp.
  • Okawa S; Department of Medical Engineering, National Defense Medical College, Tokorozawa, Saitama, Japan.
  • Hirasawa T; Department of Medical Engineering, National Defense Medical College, Tokorozawa, Saitama, Japan.
  • Kushibiki T; Department of Medical Engineering, National Defense Medical College, Tokorozawa, Saitama, Japan.
  • Sasa H; Department of Obstetrics and Gynecology, National Defense Medical College, Tokorozawa, Saitama, Japan.
  • Furuya K; Department of Obstetrics and Gynecology, National Defense Medical College, Tokorozawa, Saitama, Japan.
  • Ishihara M; Department of Medical Engineering, National Defense Medical College, Tokorozawa, Saitama, Japan.
J Surg Res ; 206(2): 325-336, 2016 12.
Article en En | MEDLINE | ID: mdl-27884326
ABSTRACT

BACKGROUND:

Arterial and venous blood gas analyses (BGAs) are essential to evaluate devices that measure biological oxygenation. The appropriate timing of blood sampling for BGA after respiratory rate (RR) change in animal experiments has not been reported. This study investigated the appropriate timing of blood sampling for BGA in ventilated rabbits and whether venous samples are an alternative to arterial samples. MATERIALS AND

METHODS:

Under general anesthesia, 14 rabbits (body weight, 3.02 ± 0.09 kg) were ventilated and their RR was changed (40/min, 30/min, and 20/min). Blood was sampled through cervical arterial and venous catheters. Experiment 1 in seven rabbits, arterial BGA was measured at 0, 0.5, 1, 2, 3, 5, 10, 15, and 20 min after the RR change. Experiment 2 in seven different rabbits, simultaneous arterial and venous BGA were measured at 0, 2, 5, 10, 15, and 20 min after the RR change.

RESULTS:

Oxygen partial pressure (PO2) and saturation (SO2) of the arterial blood stabilized 0.5 min after the RR changed. In venous BGA, no index stabilized during observation. The arterial and venous values of the carbon dioxide partial pressure (PCO2) and pH had significant correlations (arterial PCO2 = 0.9316 × venous PCO2-4.4425 [r = 0.9178]; arterial pH = 1.0835 × venous pH-0.5795 [r = 0.9453]).

CONCLUSIONS:

In ventilated rabbits, arterial PO2 and SO2 stabilized in 0.5 min. No venous value stabilized after the RR change. Only the PCO2 and pH of venous samples may be an alternative to arterial samples under the defined formula.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Oxígeno / Respiración Artificial / Dióxido de Carbono / Recolección de Muestras de Sangre / Frecuencia Respiratoria Límite: Animals Idioma: En Revista: J Surg Res Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Oxígeno / Respiración Artificial / Dióxido de Carbono / Recolección de Muestras de Sangre / Frecuencia Respiratoria Límite: Animals Idioma: En Revista: J Surg Res Año: 2016 Tipo del documento: Article