Your browser doesn't support javascript.
loading
An instrument for measuring scintillators efficiently based on silicon photomultipliers.
Yang, M J; Zhang, Z M; Wang, Y J; Li, D W; Zhou, W; Tang, H H; Liu, Y T; Chai, P; Shuai, L; Huang, X C; Liu, S Q; Zhu, M L; Jiang, X P; Zhang, Y W; Li, T; Ma, B; Sun, S F; Sun, L Y; Wang, Q; Lu, Z R; Zhang, T; Wei, L.
Afiliación
  • Yang MJ; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang ZM; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Wang YJ; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Li DW; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Zhou W; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Tang HH; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Liu YT; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Chai P; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Shuai L; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Huang XC; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Liu SQ; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Zhu ML; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Jiang XP; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang YW; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Li T; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Ma B; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Sun SF; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Sun LY; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Wang Q; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Lu ZR; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang T; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Wei L; Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
Rev Sci Instrum ; 87(11): 113308, 2016 Nov.
Article en En | MEDLINE | ID: mdl-27910308
ABSTRACT
An instrument used for measuring multiple scintillators' light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators' light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument's performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2016 Tipo del documento: Article País de afiliación: China
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2016 Tipo del documento: Article País de afiliación: China