Plasma exchange in the intensive care unit: Technical aspects and complications.
Lemaire, Aurélie; Parquet, Nathalie; Galicier, Lionel; Boutboul, David; Bertinchamp, Rémi; Malphettes, Marion; Dumas, Guillaume; Mariotte, Eric; Peraldi, Marie-Noëlle; Souppart, Virginie; Schlemmer, Benoit; Azoulay, Elie; Canet, Emmanuel.
Afiliación
  • Lemaire A; Medical Intensive Care Department, Saint Louis University Hospital, Paris, France.
  • Parquet N; Therapeutic Apheresis Department, Saint Louis University Hospital, Paris, France.
  • Galicier L; Department of Clinical Immunology, Saint Louis University Hospital, Paris, France.
  • Boutboul D; Department of Clinical Immunology, Saint Louis University Hospital, Paris, France.
  • Bertinchamp R; Department of Clinical Immunology, Saint Louis University Hospital, Paris, France.
  • Malphettes M; Department of Immuno-Hematology, Saint Louis University Hospital, Paris, France.
  • Dumas G; Medical Intensive Care Department, Saint Louis University Hospital, Paris, France.
  • Mariotte E; Medical Intensive Care Department, Saint Louis University Hospital, Paris, France.
  • Peraldi MN; Department of Nephrology and Kidney transplantation, Saint Louis University Hospital, Paris, France.
  • Souppart V; Paris Diderot University, Sorbonne Paris Cité, Paris, France.
  • Schlemmer B; Medical Intensive Care Department, Saint Louis University Hospital, Paris, France.
  • Azoulay E; Medical Intensive Care Department, Saint Louis University Hospital, Paris, France.
  • Canet E; Paris Diderot University, Sorbonne Paris Cité, Paris, France.
J Clin Apher ; 32(6): 405-412, 2017 Dec.
Article en En | MEDLINE | ID: mdl-28146331
ABSTRACT

BACKGROUND:

Data on plasma exchange therapy in the intensive care unit (ICU) setting are scarce. We aimed to describe the technical aspects and the adverse events associated with the procedure in critically ill patients.

METHODS:

All adult patients treated by plasma exchange in the medical ICU of the Saint-Louis university hospital between January 1, 2013 and March 31, 2015 were prospectively included.

RESULTS:

We report on 260 plasma exchange procedures performed in 50 patients. The centrifugation technique was used for 159 (61%) procedures and the filtration technique for the other 101 (39%) procedures. Both techniques had similar efficacy to treat hyperviscosity syndrome (n = 18). Seventy (26.9%) of the 260 plasma exchange procedures were reported with at least one adverse reaction. Centrifugation and filtration techniques had similar rates of adverse reactions (23.9 vs. 31.7%, P = .19). Hypotension was the most reported (n = 21, 8%) and correlates with a low hematocrit before therapy. Most complications were related to allergic reactions to the replacement fluids. Coagulation disorders depended on the type of replacement fluid. The post-exchange fibrinogen level was decreased by 54% [48;66] with albumin 5%, and 4% [-5;17] with plasma frozen within 24 h. Twenty-three (22.8%) of the 101 filtration procedures experienced filter clotting. Filter clotting was associated with a higher volume exchange prescribed when compared to procedures without filter clotting (4600 [4000;5000] ml vs. 3900 [3600;4800] ml, P < .01).

CONCLUSION:

Plasma exchange is a relatively safe and generally well-tolerated procedure in the ICU setting. Most adverse events are unpredictable and related to minor allergic reactions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Intercambio Plasmático / Unidades de Cuidados Intensivos Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Apher Año: 2017 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Intercambio Plasmático / Unidades de Cuidados Intensivos Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Apher Año: 2017 Tipo del documento: Article País de afiliación: Francia