Your browser doesn't support javascript.
loading
The effect of fluid resuscitation on the effective circulating volume in patients undergoing liver surgery: a post-hoc analysis of a randomized controlled trial.
Vos, Jaap Jan; Kalmar, A F; Hendriks, H G D; Bakker, J; Scheeren, T W L.
Afiliación
  • Vos JJ; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, PO Box 30001, 9700RB, Groningen, Netherlands. j.j.vos@umcg.nl.
  • Kalmar AF; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, PO Box 30001, 9700RB, Groningen, Netherlands.
  • Hendriks HGD; Department of Anesthesia and Critical Care Medicine, Maria Middelares Hospital, Ghent, Belgium.
  • Bakker J; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, PO Box 30001, 9700RB, Groningen, Netherlands.
  • Scheeren TWL; Department of Intensive Care Adults, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
J Clin Monit Comput ; 32(1): 73-80, 2018 Feb.
Article en En | MEDLINE | ID: mdl-28210935
To assess the significance of an analogue of the mean systemic filling pressure (Pmsa) and its derived variables, in providing a physiology based discrimination between responders and non-responders to fluid resuscitation during liver surgery. A post-hoc analysis of data from 30 patients undergoing major hepatic surgery was performed. Patients received 15 ml kg-1 fluid in 30 min. Fluid responsiveness (FR) was defined as an increase of 20% or greater in cardiac index, measured by FloTrac-Vigileo®. Dynamic preload variables (pulse pressure variation and stroke volume variation: PPV, SVV) were recorded additionally. Pvr, the driving pressure for venous return (=Pmsa-central venous pressure) and heart performance (EH; Pvr/Pmsa) were calculated according to standard formula. Pmsa increased following fluid administration in responders (n = 18; from 13 ± 3 to 17 ± 4 mmHg, p < 0.01) and in non-responders (n = 12; from 14 ± 4 to 17 ± 4 mmHg, p < 0.01). Pvr, which was lower in responders before fluid administration (6 ± 1 vs. 7 ± 1 mmHg; p = 0.02), increased after fluid administration only in responders (from 6 ± 1 to 8 ± 1 mmHg; p < 0.01). EH only decreased in non-responders (from 0.56 ± 0.17 to 0.45 ± 0.12; p < 0.05). The area under the receiver operating characteristics curve of Pvr, PPV and SVV for predicting FR was 0.75, 0.73 and 0.72, respectively. Changes in Pmsa, Pvr and EH reflect changes in effective circulating volume and heart performance following fluid resuscitation, providing a physiologic discrimination between responders and non-responders. Also, Pvr predicts FR equivalently compared to PPV and SVV, and might therefore aid in predicting FR in case dynamic preload variables cannot be used.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Volumen Sistólico / Presión Venosa Central / Fluidoterapia / Hígado Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Volumen Sistólico / Presión Venosa Central / Fluidoterapia / Hígado Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos