Your browser doesn't support javascript.
loading
3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.
Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M.
Afiliación
  • Mediratta A; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Addetia K; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Medvedofsky D; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Schneider RJ; Philips Healthcare, Andover, MA, USA.
  • Kruse E; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Shah AP; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Nathan S; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Paul JD; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Blair JE; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Ota T; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Balkhy HH; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Patel AR; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Mor-Avi V; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
  • Lang RM; Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA.
Echocardiography ; 34(5): 690-699, 2017 May.
Article en En | MEDLINE | ID: mdl-28345211

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Programas Informáticos / Interpretación de Imagen Asistida por Computador / Ecocardiografía Tridimensional / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: Echocardiography Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Programas Informáticos / Interpretación de Imagen Asistida por Computador / Ecocardiografía Tridimensional / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: Echocardiography Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos