Your browser doesn't support javascript.
loading
Determination of the appropriate oropharyngeal airway size in adults: Assessment using ventilation and an endoscopic view.
Kim, Hyun Joo; Kim, Shin Hyung; Min, Ji Young; Park, Wyun Kon.
Afiliación
  • Kim HJ; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Electronic address: jjollong@gmail.com.
  • Kim SH; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Electronic address: TESSAR@yuhs.ac.
  • Min JY; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Electronic address: EARLKAIN@yuhs.ac.
  • Park WK; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Electronic address: wkp7ark@yuhs.ac.
Am J Emerg Med ; 35(10): 1430-1434, 2017 Oct.
Article en En | MEDLINE | ID: mdl-28529003
ABSTRACT

INTRODUCTION:

Size 9 and 8 airways for men and women, respectively, have been proposed as most appropriate based on endoscopy. However, a limitation of this guideline is that ventilation was not assessed.

METHODS:

In this retrospective review of prospectively collected data, 149 patients requiring tracheal intubation for general anesthesia were included. The adequacy for manual and pressure-controlled mechanical ventilation and views at the distal end of each airway was assessed using a fiber-optic bronchoscope with various airway sizes (7, 8, 9, 10, and 11).

RESULTS:

For men, size 9, 10, and 11 airways permitted clear manual and adequate mechanical ventilation; size 7 and 8 airways caused partially obstructed manual and inadequate mechanical ventilation. On endoscopy, size 7 and 8 airways caused complete obstruction by the tongue; size 10 and 11 airways either touched or passed beyond the tip of the epiglottis. For women, the size 7 airway caused partially obstructed manual and inadequate mechanical ventilation; size 9 and 10 airways provided clear manual and adequate mechanical ventilation. The size 8 airway permitted clear manual ventilation, though mechanical ventilation was inadequate in one patient. On endoscopy, the size 7 airway caused complete obstruction in >50% of women; size 9, 10, and 11 airways either touched or passed beyond the tip of the epiglottis.

CONCLUSIONS:

With respect to adequate ventilation in conjunction with an acceptable endoscopic view, size 9 and size 8 oropharyngeal airways appear to be the most appropriate sizes for clinical use in men and women, respectively.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Orofaringe / Respiración Artificial / Broncoscopía / Intubación Intratraqueal / Anestesia General Tipo de estudio: Guideline / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Emerg Med Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Orofaringe / Respiración Artificial / Broncoscopía / Intubación Intratraqueal / Anestesia General Tipo de estudio: Guideline / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Emerg Med Año: 2017 Tipo del documento: Article