Emergency Decompression of Orbital Emphysema with Elevated Intraorbital Pressure.
J Emerg Med
; 53(3): 405-407, 2017 Sep.
Article
en En
| MEDLINE
| ID: mdl-28992871
BACKGROUND: A case of orbital emphysema associated with elevated intraorbital pressure, presenting as a complication of a paranasal sinus "blow-out" fracture after trauma to the orbit and globe is presented. CASE REPORT: A 45-year-old man developed left globe rupture with orbital emphysema after blunt trauma. A large air pocket in the superior orbit with medial wall fracture and globe tenting was identified on noncontrast computed tomography. Direct needle drainage was performed using a 23-gauge needle attached to a saline-filled syringe with the plunger removed. Rapid release of air bubbles with prompt alleviation of pressure symptoms was observed. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Early diagnosis and management of orbital emphysema can salvage useful function of the globe. The knowledge of this clinical entity and its management can prevent delay and unnecessary referral.