Your browser doesn't support javascript.
loading
Ultrahigh-resolution optical coherence elastography through a micro-endoscope: towards in vivo imaging of cellular-scale mechanics.
Fang, Qi; Curatolo, Andrea; Wijesinghe, Philip; Yeow, Yen Ling; Hamzah, Juliana; Noble, Peter B; Karnowski, Karol; Sampson, David D; Ganss, Ruth; Kim, Jun Ki; Lee, Woei M; Kennedy, Brendan F.
Afiliación
  • Fang Q; BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Curatolo A; School of Electrical, Electronic & Computer Engineering, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Wijesinghe P; BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Yeow YL; School of Electrical, Electronic & Computer Engineering, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Hamzah J; BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Noble PB; Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Karnowski K; Targeted Drug Delivery, Imaging and Therapy, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Sampson DD; Targeted Drug Delivery, Imaging and Therapy, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Ganss R; School of Human Sciences, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Kim JK; Centre for Neonatal Research & Education, School of Paediatrics and Child Health, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Lee WM; Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, Perth, Western Australia 6009, Australia.
  • Kennedy BF; Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, Perth, Western Australia 6009, Australia.
Biomed Opt Express ; 8(11): 5127-5138, 2017 Nov 01.
Article en En | MEDLINE | ID: mdl-29188108
ABSTRACT
In this paper, we describe a technique capable of visualizing mechanical properties at the cellular scale deep in living tissue, by incorporating a gradient-index (GRIN)-lens micro-endoscope into an ultrahigh-resolution optical coherence elastography system. The optical system, after the endoscope, has a lateral resolution of 1.6 µm and an axial resolution of 2.2 µm. Bessel beam illumination and Gaussian mode detection are used to provide an extended depth-of-field of 80 µm, which is a 4-fold improvement over a fully Gaussian beam case with the same lateral resolution. Using this system, we demonstrate quantitative elasticity imaging of a soft silicone phantom containing a stiff inclusion and a freshly excised malignant murine pancreatic tumor. We also demonstrate qualitative strain imaging below the tissue surface on in situ murine muscle. The approach we introduce here can provide high-quality extended-focus images through a micro-endoscope with potential to measure cellular-scale mechanics deep in tissue. We believe this tool is promising for studying biological processes and disease progression in vivo.