Transvenous dual-chamber pacemaker after paediatric heart transplantation using left ventricle pacing through the coronary sinus.
ESC Heart Fail
; 5(1): 204-207, 2018 02.
Article
en En
| MEDLINE
| ID: mdl-29356392
ABSTRACT
A 12-year-old child with end-stage heart failure due to restrictive cardiomyopathy was submitted to orthotopic heart transplantation. Primary graft dysfunction required venous arterial extra-corporeal membrane oxygenation. Heart function normalized, but complete atrioventricular block remained after 3 weeks. A dual-chamber pacing with transvenous left ventricle pacing through the coronary sinus was performed. At 5-year follow-up, the patient is stable with the same pacing system and with preserved ventricular function.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Marcapaso Artificial
/
Trasplante de Corazón
/
Bloqueo Atrioventricular
/
Disfunción Primaria del Injerto
Tipo de estudio:
Etiology_studies
Límite:
Child
/
Female
/
Humans
Idioma:
En
Revista:
ESC Heart Fail
Año:
2018
Tipo del documento:
Article
País de afiliación:
Brasil