ABSTRACT
We present an unusual case where symptoms of headache and chest pain persisted for 3 years following the implantation of a septal occluder device for an atrial septal defect despite endothelialisation of the device. The patient was found to have nickel hypersensitivity on patch testing. Following the removal of the device the patient had complete resolution of headaches and chest pain up to 10 months post-explantation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dispositivo Oclusor Septal / Hipersensibilidad / Níquel Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans Idioma: En Revista: Australas J Dermatol Año: 2018 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dispositivo Oclusor Septal / Hipersensibilidad / Níquel Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans Idioma: En Revista: Australas J Dermatol Año: 2018 Tipo del documento: Article País de afiliación: Australia