Your browser doesn't support javascript.
loading
Assessment of patient's peak skin dose during abdominopelvic embolization using radiochromic (Gafchromic) films.
Greffier, J; Goupil, J; Larbi, A; Stefanovic, X; Pereira, F; Moliner, G; Ovtchinnikoff, S; Beregi, J P; Frandon, J.
Afiliación
  • Greffier J; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France. Electronic address: joel.greffier@chu-nimes.fr.
  • Goupil J; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Larbi A; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Stefanovic X; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Pereira F; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Moliner G; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Ovtchinnikoff S; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Beregi JP; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
  • Frandon J; EA 2415, department of radiology, Nîmes university hospital, medical imaging group Nîmes, CHU de Nîmes, boulevard Prof. Robert-Debré, 30029 Nîmes cedex, France.
Diagn Interv Imaging ; 99(5): 321-329, 2018 May.
Article en En | MEDLINE | ID: mdl-29396087
ABSTRACT

PURPOSE:

To assess the value of the routine use of radiochromic films in abdominopelvic embolization procedures to improve patient follow-up.

METHODS:

A total of 55 patients who underwent transcatheter abdominopelvic embolization were prospectively included. Six types of procedures were evaluated including hepatic chemoembolization (HCE), gonadal veins embolization (GVE), uterine elective embolization (UEE), uterine urgent embolization (UUE), abdominal elective embolization (AEE), and abdominal urgent embolization (AUE). Dosimetric indicators (DIs) such as air-kerma (AK) and kerma-area-product (KAP) were collected and peak skin dose (PSD) was measured with radiochromic films. Correlations between PSD and DIs were searched for.

RESULTS:

The mean (±standard deviation [SD]) PSD for the various procedures were 1033±502 mGy for HCE; 476±271 mGy for GVE; 460±171 mGy for UEE; 531±263 mGy for UUE; 708±896 mGy for AEE; 683±392 mGy for AUE. Strong correlations were observed between PSD and DIs (r=0.974 for AK and r=0.925 for KAP). PSD was>2Gy in one procedure and all procedures (7/132) procedures resulted in AK>2Gy, mostly for HCE and AEE.

CONCLUSION:

Dosimetry using radiochromic film is only appropriate for HCE, AEE and AUE, whereas dose-mapping systems present a more suitable solution for all embolizations including those with AK that occasionally exceed 2Gy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Radiografía Intervencional / Embolización Terapéutica Tipo de estudio: Observational_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Radiografía Intervencional / Embolización Terapéutica Tipo de estudio: Observational_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Año: 2018 Tipo del documento: Article