Your browser doesn't support javascript.
loading
Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis.
Aljabab, Saif; Vellayappan, Balamurugan; Vandervoort, Eric; Bahm, Jamie; Zohr, Robert; Sinclair, John; Caudrelier, Jean-Michel; Szanto, Janos; Malone, Shawn.
Afiliación
  • Aljabab S; Radiation Medicine Program, The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada.
  • Vellayappan B; Division of Radiation Oncology, National University Cancer Institute, Singapore.
  • Vandervoort E; Radiation Medicine Program, The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada.
  • Bahm J; Radiation Medicine Program, The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada.
  • Zohr R; Radiation Medicine Program, The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada.
  • Sinclair J; Division of Neurosurgery, University of Ottawa, Ottawa, ON, Canada.
  • Caudrelier JM; Radiation Medicine Program, The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada.
  • Szanto J; Ottawa Hospital Research Institute, Ottawa, ON, Canada.
  • Malone S; Division of Radiation Oncology, Department of Radiology, University of Ottawa, Ottawa, ON, Canada.
J Appl Clin Med Phys ; 19(2): 160-167, 2018 Mar.
Article en En | MEDLINE | ID: mdl-29417728
PURPOSE: The aim of this study is to compare the dosimetric differences between four techniques for spine stereotactic body radiotherapy (SBRT): CyberKnife (CK), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) with dynamic jaws (HT-D) and fixed jaws (HT-F). MATERIALS/METHODS: Data from 10 patients were utilized. All patients were planned for 24 Gy in two fractions, with the primary objectives being: (a) restricting the maximum dose to the cord to ≤ 17 Gy and/or cauda equina to ≤ 20 Gy, and (b) to maximize the clinical target volume (CTV) to receive the prescribed dose. Treatment plans were generated by separate dosimetrists and then compared using velocity AI. Parameters of comparison include target volume coverage, conformity index (CI), gradient index (GI), homogeneity index (HI), treatment time (TT) per fraction, and monitor units (MU) per fraction. RESULTS: PTV D2 and D5 were significantly higher for CK compared to VMAT, HT-F, and HT-D (P < 0.001). The average volume of CTV receiving the prescription dose (CTV D95) was significantly less for VMAT compared to CK, HT-F and HT-D (P = 0.036). CI improved for CK (0.69), HT-F (0.66), and HT-D (0.67) compared to VMAT (0.52) (P = 0.013). CK (41.86) had the largest HI compared to VMAT (26.99), HT-F (20.69), and HT-D (21.17) (P < 0.001). GI was significantly less for CK (3.96) compared to VMAT (6.76) (P = 0.001). Likewise, CK (62.4 min, 14059 MU) had the longest treatment time and MU per fraction compared to VMAT (8.5 min, 9764 MU), HT-F (13 min, 10822 MU), and HT-D (13.5 min, 11418 MU) (P < 0.001). CONCLUSION: Both CK and HT plans achieved conformal target coverage while respecting cord tolerance. Dose heterogeneity was significantly larger in CK. VMAT required the least treatment time and MU output, but had the least steep GI, CI, and target coverage.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Columna Vertebral / Planificación de la Radioterapia Asistida por Computador / Radiocirugia Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2018 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Columna Vertebral / Planificación de la Radioterapia Asistida por Computador / Radiocirugia Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2018 Tipo del documento: Article País de afiliación: Canadá