Your browser doesn't support javascript.
loading
Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images.
Queirós, Sandro; Morais, Pedro; Dubois, Christophe; Voigt, Jens-Uwe; Fehske, Wolfgang; Kuhn, Andreas; Achenbach, Tobias; Fonseca, Jaime C; Vilaça, João L; D'hooge, Jan.
Afiliación
  • Queirós S; Lab on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium; Life and Health Sciences Research Institute, School of Medicine, University of Minho, Braga, Portugal; Algoritmi Center, School of Engineering, University of Minho, Guimarães, Portugal; ICVS/3B's - PT Government Associate Labora
  • Morais P; Lab on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium; Life and Health Sciences Research Institute, School of Medicine, University of Minho, Braga, Portugal; ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal; Instituto de Ciência e Inovação em Engenharia Mecâ
  • Dubois C; Department of Cardiovascular Diseases, University Hospital Leuven, and Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
  • Voigt JU; Department of Cardiovascular Diseases, University Hospital Leuven, and Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
  • Fehske W; Department of Cardiology, St. Vinzenz-Hospital, Cologne, Germany; Institute of Diagnostic and Interventional Radiology, St. Vinzenz-Hospital, Cologne, Germany.
  • Kuhn A; Department of Cardiology, St. Vinzenz-Hospital, Cologne, Germany; Institute of Diagnostic and Interventional Radiology, St. Vinzenz-Hospital, Cologne, Germany.
  • Achenbach T; Institute of Diagnostic and Interventional Radiology, St. Vinzenz-Hospital, Cologne, Germany.
  • Fonseca JC; Algoritmi Center, School of Engineering, University of Minho, Guimarães, Portugal.
  • Vilaça JL; Life and Health Sciences Research Institute, School of Medicine, University of Minho, Braga, Portugal; ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal; 2Ai- Polytechnic Institute of Cávado and Ave, Barcelos, Portugal.
  • D'hooge J; Lab on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium.
J Am Soc Echocardiogr ; 31(4): 515-525.e5, 2018 04.
Article en En | MEDLINE | ID: mdl-29625649
BACKGROUND: Accurate aortic annulus (AoA) sizing is crucial for transcatheter aortic valve implantation planning. Three-dimensional (3D) transesophageal echocardiography (TEE) is a viable alternative to the standard multidetector row computed tomography (MDCT) for such assessment, with few automatic software solutions available. The aim of this study was to present and evaluate a novel software tool for automatic AoA sizing by 3D TEE. METHODS: One hundred one patients who underwent both preoperative MDCT and 3D TEE were retrospectively analyzed using the software. The automatic software measurements' accuracy was compared against values obtained using standard manual MDCT, as well as against those obtained using manual 3D TEE, and intraobserver, interobserver, and test-retest reproducibility was assessed. Because the software can be used as a fully automatic or as an interactive tool, both options were addressed and contrasted. The impact of these measures on the recommended prosthesis size was then evaluated to assess if the software's automated sizes were concordant with those obtained using an MDCT- or a TEE-based manual sizing strategy. RESULTS: The software showed very good agreement with manual values obtained using MDCT and 3D TEE, with the interactive approach having slightly narrower limits of agreement. The latter also had excellent intra- and interobserver variability. Both fully automatic and interactive analyses showed excellent test-retest reproducibility, with the first having a faster analysis time. Finally, either approach led to good sizing agreement against the true implanted sizes (>77%) and against MDCT-based sizes (>88%). CONCLUSIONS: Given the automated, reproducible, and fast nature of its analyses, the novel software tool presented here may potentially facilitate and thus increase the use of 3D TEE for preoperative transcatheter aortic valve implantation sizing.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Programas Informáticos / Ecocardiografía Transesofágica / Ecocardiografía Tridimensional / Tomografía Computarizada Multidetector / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Programas Informáticos / Ecocardiografía Transesofágica / Ecocardiografía Tridimensional / Tomografía Computarizada Multidetector / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article