Your browser doesn't support javascript.
loading
Rapid systematic review shows that using a high-flow nasal cannula is inferior to nasal continuous positive airway pressure as first-line support in preterm neonates.
Conte, Francesca; Orfeo, Luigi; Gizzi, Camilla; Massenzi, Luca; Fasola, Salvatore.
Afiliación
  • Conte F; Neonatal Intensive Care Unit, San Giovanni Calibita Fatebenefratelli Hospital, Rome, Italy.
  • Orfeo L; Neonatal Intensive Care Unit, San Giovanni Calibita Fatebenefratelli Hospital, Rome, Italy.
  • Gizzi C; Neonatal Intensive Care Unit, Azienda Ospedaliera Regionale San Carlo, Potenza, Italy.
  • Massenzi L; Neonatal Intensive Care Unit, San Giovanni Calibita Fatebenefratelli Hospital, Rome, Italy.
  • Fasola S; Institute of Biomedicine and Molecular Immunology, National Research Council of Italy, Palermo, Italy.
Acta Paediatr ; 107(10): 1684-1696, 2018 10.
Article en En | MEDLINE | ID: mdl-29751368
ABSTRACT

AIM:

We reviewed using a high-flow nasal cannula (HFNC) as first-line support for preterm neonates with, or at risk of, respiratory distress.

METHODS:

This rapid systematic review covered biomedical databases up to June 2017. We included randomised controlled trials (RCTs) published in English. The reference lists of the studies and relevant reviews we included were also screened. We performed the study selection, data extraction, study quality assessment, meta-analysis and quality of evidence assessment following the Grading of Recommendations Assessment, Development and Evaluation system.

RESULTS:

Pooled results from six RCTs covering 1227 neonates showed moderate-quality evidence that HFNC was associated with a higher rate of failure than nasal continuous positive airway pressure (NCPAP) in preterm neonates of at least 28 weeks of gestation, with a risk ratio of 1.57. Low-quality evidence showed no significant differences between HFNC and NCPAP in the need for intubation and bronchopulmonary dysplasia rate. HFNC yielded a lower rate of nasal injury (risk ratio 0.50). When HFNC failed, intubation was avoided in some neonates by switching them to NCPAP.

CONCLUSION:

HFNC had higher failure rates than NCPAP when used as first-line support. Subsequently switching to NCPAP sometimes avoided intubation. Data on the most immature neonates were lacking.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Presión de las Vías Aéreas Positiva Contínua / Ventilación no Invasiva Tipo de estudio: Clinical_trials / Systematic_reviews Límite: Humans / Newborn Idioma: En Revista: Acta Paediatr Año: 2018 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Presión de las Vías Aéreas Positiva Contínua / Ventilación no Invasiva Tipo de estudio: Clinical_trials / Systematic_reviews Límite: Humans / Newborn Idioma: En Revista: Acta Paediatr Año: 2018 Tipo del documento: Article País de afiliación: Italia