Your browser doesn't support javascript.
loading
Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study.
Burghard, Philipp; Plank, Fabian; Beyer, Christoph; Müller, Silvana; Dörler, Jakob; Zaruba, Marc-Michael; Pölzl, Leo; Pölzl, Gerhard; Klauser, Andrea; Rauch, Stefan; Barbieri, Fabian; Langer, Christian-Ekkehardt; Schgoer, Wilfried; Williamson, Eric E; Feuchtner, Gudrun.
Afiliación
  • Burghard P; Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria. philipp.burghard@hotmail.com.
  • Plank F; , Breitenwangerstrasse 19, 6600, Reutte, Austria. philipp.burghard@hotmail.com.
  • Beyer C; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Müller S; Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Dörler J; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Zaruba MM; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Pölzl L; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Pölzl G; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Klauser A; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Rauch S; Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Barbieri F; Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Langer CE; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Schgoer W; Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Williamson EE; Department of Internal Medicine III, Innsbruck Medical University, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Feuchtner G; Department of Radiology, Mayo Clinic Rochester, Minnesota, 200 1st St SW, Rochester, MN, 55902, USA.
Eur Radiol ; 28(12): 5129-5136, 2018 Dec.
Article en En | MEDLINE | ID: mdl-29869175
ABSTRACT

OBJECTIVES:

To evaluate right ventricle (RV) function by coronary computed tomography angiography (CTA) using a novel automated three-dimensional (3D) RV volume segmentation tool in comparison with clinical reference modalities.

METHODS:

Twenty-six patients with severe end-stage heart failure [left ventricle (LV) ejection fraction (EF) <35%] referred to CTA were enrolled. A specific individually tailored biphasic contrast agent injection protocol was designed (80%/20% high/low flow) was designed. Measurement of RV function [EF, end-diastolic volume (EDV), end-systolic volume (ESV)] by CTA was compared with tricuspid annular plane systolic excursion (TAPSE) by transthoracic echocardiography (TTE) and right heart invasive catheterisation (IC).

RESULTS:

Automated 3D RV volume segmentation was successful in 26 (100%) patients. Read-out time was 3 min 33 s (range, 1 min 50s-4 min 33s). RV EF by CTA was stronger correlated with right atrial pressure (RAP) by IC (r = -0.595; p = 0.006) but weaker with TAPSE (r = 0.366, p = 0.94). When comparing TAPSE with RAP by IC (r = -0.317, p = 0.231), a weak-to-moderate non-significant inverse correlation was found. Interobserver correlation was high with r = 0.96 (p < 0.001), r = 0.86 (p < 0.001) and r = 0.72 (p = 0.001) for RV EDV, ESV and EF, respectively. CT attenuation of the right atrium (RA) and right ventricle (RV) was 196.9 ± 75.3 and 217.5 ± 76.1 HU, respectively.

CONCLUSIONS:

Measurement of RV function by CTA using a novel 3D volumetric segmentation tool is fast and reliable by applying a dedicated biphasic injection protocol. The RV EF from CTA is a closer surrogate of RAP than TAPSE by TTE. KEY POINTS • Evaluation of RV function by cardiac CTA by using a novel 3D volume segmentation tool is fast and reliable. • A biphasic contrast agent injection protocol ensures homogenous RV contrast attenuation. • Cardiac CT is a valuable alternative modality to CMR for the evaluation of RV function.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Función Ventricular Derecha / Angiografía por Tomografía Computarizada / Insuficiencia Cardíaca Tipo de estudio: Evaluation_studies / Guideline Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Función Ventricular Derecha / Angiografía por Tomografía Computarizada / Insuficiencia Cardíaca Tipo de estudio: Evaluation_studies / Guideline Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Austria