Your browser doesn't support javascript.
loading
Assessment of left ventricular size and function by 3-dimensional transthoracic echocardiography: Impact of the echocardiography platform and analysis software.
Castel, Anne Laure; Toledano, Manuel; Tribouilloy, Christophe; Delelis, François; Mailliet, Amandine; Marotte, Nathalie; Guerbaai, Raphaëlle A; Levy, Franck; Graux, Pierre; Ennezat, Pierre-Vladimir; Maréchaux, Sylvestre.
Afiliación
  • Castel AL; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France.
  • Toledano M; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Département D'imagerie Médicale, Université Catholique de Lille, Lille, France.
  • Tribouilloy C; Centre Hospitalier Universitaire d'Amiens, Amiens, France; Centre Universitaire de Recherche en Santé, Laboratoire MP3CV - EA 7517, Université de Picardie, Amiens, France.
  • Delelis F; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France.
  • Mailliet A; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France.
  • Marotte N; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France.
  • Guerbaai RA; Department Public Health (DPH), Faculty of Medicine, University of Basel, Basel, Switzerland.
  • Levy F; Centre Cardiothoracique de Monaco, Avenue d'Ostende, Monaco.
  • Graux P; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France.
  • Ennezat PV; Centre Hospitalier Universitaire de Grenoble, Grenoble, France.
  • Maréchaux S; Université Lille Nord de France, GCS-Groupement des Hôpitaux de l'Institut Catholique de Lille, Laboratoire D'échocardiographie, Service de Cardiologie Nord, Centre des Valvulopathies, Faculté Libre de Médecine, Université Catholique de Lille, Lille, France; Centre Hospitalier Universitaire d'Amiens
Am Heart J ; 202: 127-136, 2018 08.
Article en En | MEDLINE | ID: mdl-29935472
ABSTRACT

BACKGROUND:

Whether echocardiography platform and analysis software impact left ventricular (LV) volumes, ejection fraction (EF), and stroke volume (SV) by transthoracic tridimensional echocardiography (3DE) has not yet been assessed. Hence, our aim was to compare 3DE LV end-diastolic and end-systolic volumes (EDV and ESV), LVEF, and SV obtained with echocardiography platform from 2 different manufacturers.

METHODS:

3DE was performed in 84 patients (65% of screened consecutive patients), with equipment from 2 different manufacturers, with subsequent off-line postprocessing to obtain parameters of LV function and size (Philips QLAB 3DQ and General Electric EchoPAC 4D autoLVQ). Twenty-five patients with clinical indication for cardiac magnetic resonance imaging served as a validation subgroup.

RESULTS:

LVEDV and LVESV from 2 vendors were highly correlated (r = 0.93), but compared with 4D autoLVQ, the use of Qlab 3DQ resulted in lower LVEDV and LVESV (bias 11 mL, limits of agreement -25 to +47 and bias 6 mL, limits of agreement -22 to +34, respectively). The agreement between LVEF values of each software was poor (intraclass correlation coefficient 0.62) despite no or minimal bias. SVs were also lower with Qlab 3DQ advanced compared with 4D autoLVQ, and both were poorly correlated (r = 0.66). Consistently, the underestimation of LVEDV, LVESV, and SV by 3DE compared with cardiac magnetic resonance imaging was more pronounced with Philips QLAB 3DQ advanced than with 4D autoLVQ.

CONCLUSIONS:

The echocardiography platform and analysis software significantly affect the values of LV parameters obtained by 3DE. Intervendor standardization and improvements in 3DE modalities are needed to broaden the use of LV parameters obtained by 3DE in clinical practice.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Programas Informáticos / Función Ventricular Izquierda / Ecocardiografía Tridimensional / Ventrículos Cardíacos Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am Heart J Año: 2018 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Programas Informáticos / Función Ventricular Izquierda / Ecocardiografía Tridimensional / Ventrículos Cardíacos Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am Heart J Año: 2018 Tipo del documento: Article País de afiliación: Francia