Your browser doesn't support javascript.
loading
Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review.
Driessen, Sarah; Napp, Andreas; Schmiedchen, Kristina; Kraus, Thomas; Stunder, Dominik.
Afiliación
  • Driessen S; Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany.
  • Napp A; Department of Internal Medicine I (Cardiology, Angiology, Pneumology and Internal Intensive Care Medicine), University Hospital, RWTH Aachen University, Aachen, Germany.
  • Schmiedchen K; Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany.
  • Kraus T; Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany.
  • Stunder D; Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany.
Europace ; 21(2): 219-229, 2019 Feb 01.
Article en En | MEDLINE | ID: mdl-29992289
ABSTRACT
Electromagnetic fields (EMF) in the intermediate frequency (IF) range are generated by many novel electrical appliances, including electric vehicles, radiofrequency identification systems, induction hobs, or energy supply systems, such as wireless charging systems. The aim of this systematic review is to evaluate whether cardiovascular implantable electronic devices (CIEDs) are susceptible to electromagnetic interference (EMI) in the IF range (1 kHz-1 MHz). Additionally, we discuss the advantages and disadvantages of the different types of studies used to investigate EMI. Using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, we collected and evaluated studies examining EMI in in vivo studies, in vitro studies (phantom studies, benchmark tests), and simulation studies. Our analysis revealed that cardiac implants are susceptible to malfunction induced by EMF in the IF range. Electromagnetic interference may in particular be provoked by security systems and induction hobs. The results of the studies evaluated in this systematic review further indicate that the likelihood for EMI is dependent on exposure-related parameters (field strength, frequency, and modulation) and on implant- as well as on lead-related parameters (model, type of implant, implant sensitivity setting, lead configuration, and implantation site). The review shows that the factors influencing EMI are not sufficiently characterized and EMF limit values for CIED patients cannot be derived yet. Future studies should therefore, consider exposure-related parameters as well as implant- and lead-related parameters systematically. Additionally, worst-case scenarios should be considered in all study types where possible.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Falla de Prótesis / Desfibriladores Implantables / Campos Electromagnéticos / Exposición a Riesgos Ambientales Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Límite: Animals / Humans Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Falla de Prótesis / Desfibriladores Implantables / Campos Electromagnéticos / Exposición a Riesgos Ambientales Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Límite: Animals / Humans Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Alemania