Your browser doesn't support javascript.
loading
Multiplexed detection of DOCK8, PGM3 and STAT3 proteins for the diagnosis of Hyper-Immunoglobulin E syndrome using gold nanoparticles-based immunosensor array platform.
Eissa, Shimaa; Abdulkarim, Haya; Dasouki, Majed; Al Mousa, Hamoud; Arnout, Rand; Al Saud, Bandar; Rahman, Anas Abdel; Zourob, Mohammed.
Afiliación
  • Eissa S; Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia.
  • Abdulkarim H; Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia.
  • Dasouki M; King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh 11211, Saudi Arabia.
  • Al Mousa H; Section of Pediatric Allergy and Immunology, Department of Pediatrics, King Faisal Specialist Hospital & Research Centre (KFSH-RC), Riyadh, Saudi Arabia.
  • Arnout R; Section of Pediatric Allergy and Immunology, Department of Pediatrics, King Faisal Specialist Hospital & Research Centre (KFSH-RC), Riyadh, Saudi Arabia.
  • Al Saud B; Section of Pediatric Allergy and Immunology, Department of Pediatrics, King Faisal Specialist Hospital & Research Centre (KFSH-RC), Riyadh, Saudi Arabia.
  • Rahman AA; King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh 11211, Saudi Arabia.
  • Zourob M; Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia; King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh 11211, Saudi Arabia. Electronic address: mzourob@alfaisal.edu.
Biosens Bioelectron ; 117: 613-619, 2018 Oct 15.
Article en En | MEDLINE | ID: mdl-30005381
Multiplexed biosensors hold great promise for early diagnosis of diseases where the detection of multiple biomarkers is required. Hyper Immunoglobulin E syndromes (HIES) are rare primary immunodeficiency disorders associated with mutations either in the signal transducer and activator of transcription 3 (STAT3), dedicator of cytokinesis 8 DOCK8) or phosphoglucomutase 3 (PGM3) genes. Yet, the diagnosis of HIES is challenged by the complexity of the existing laboratory assays. Here, we report for the first time the development of a multiplexed electrochemical immunosensor for the simultaneous detection of DOCK8, STAT3 and PGM3 proteins. The immunosensor was constructed on carbon array electrodes that were first modified by electrodeposition of gold nanoparticles (AuNPs). The array electrodes were then used to immobilize specific antibodies for the three proteins after the functionalization of the electrodes with cysteamine/glutaraldehyde linkers. The simultaneous detection of the DOCK8, PGM3 and STAT3 proteins was successfully realized by the immunosensor with respective limits of detections of 3.1, 2.2 and 3.5 pg/ml. The immunosensor has shown good sensitivity as well as selectivity against other proteins such as cystic fibrosis transmembrane conductance regulator (CFTR) and Duchenne Muscular Dystrophy (DMD). Moreover, the immunosensor was successfully applied in human serum samples showing capability to distinguish the HIES from the control samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Análisis Químico de la Sangre / Técnicas Biosensibles / Síndrome de Job Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Arabia Saudita

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Análisis Químico de la Sangre / Técnicas Biosensibles / Síndrome de Job Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Arabia Saudita