Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis.
Roh, Albert T; Xiao, Zhibo; Cheng, Joseph Y; Vasanawala, Shreyas S; Loening, Andreas M.
Afiliación
  • Roh AT; Radiology, Stanford University, 300 Pasteur Drive, Stanford, CA, 94305, USA.
  • Xiao Z; Radiology, First Affiliated Hospital, Chongqing, China.
  • Cheng JY; Radiology, Stanford University, 300 Pasteur Drive, Stanford, CA, 94305, USA.
  • Vasanawala SS; Radiology, Stanford University, 300 Pasteur Drive, Stanford, CA, 94305, USA.
  • Loening AM; Radiology, Stanford University, 300 Pasteur Drive, Stanford, CA, 94305, USA. loening@stanford.edu.
Abdom Radiol (NY) ; 44(1): 22-30, 2019 01.
Article en En | MEDLINE | ID: mdl-30066168
ABSTRACT

PURPOSE:

Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis.

METHODS:

Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (- 3 to + 3 scale). Scores were compared using Kruskal-Wallis and Wilcoxon signed-rank tests.

RESULTS:

UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001).

CONCLUSIONS:

In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Apendicitis / Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador Tipo de estudio: Observational_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Abdom Radiol (NY) Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Apendicitis / Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador Tipo de estudio: Observational_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Abdom Radiol (NY) Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos