Your browser doesn't support javascript.
loading
Continuous invasive hemodynamic monitoring using steerable guide catheter to optimize mitraclip transcatheter mitral valve repair: A multicenter, proof-of-concept study.
Tang, Gilbert H L; Ong, Lawrence Y; Kaple, Ryan; Ramlawi, Basel; Dutta, Tanya; Zaid, Syed; Ahmad, Hasan; Kalimi, Robert; Undemir, Cenap; Khan, Asaad; Yudi, Matias B; Nadir, M Adnan; Majeed, Farhan; Ali, Omar; Skiles, Jeffrey; Bhim, Chandra; Cohen, Martin; Lansman, Steven L; Sharma, Samin K; Kini, Annapoorna.
Afiliación
  • Tang GHL; Department of Cardiovascular Surgery, Mount Sinai Health System, New York, New York.
  • Ong LY; Department of Cardiology, Northwell Health System, Bayshore, New York.
  • Kaple R; Division of Cardiology, Westchester Medical Center, Valhalla, New York.
  • Ramlawi B; Heart and Vascular Center, Valley Health System, Winchester, Virginia.
  • Dutta T; Division of Cardiology, Westchester Medical Center, Valhalla, New York.
  • Zaid S; Division of Cardiology, Westchester Medical Center, Valhalla, New York.
  • Ahmad H; Division of Cardiology, Westchester Medical Center, Valhalla, New York.
  • Kalimi R; Department of Cardiology, Northwell Health System, Bayshore, New York.
  • Undemir C; Section of Cardiothoracic Surgery, Westchester Medical Center, Valhalla, New York.
  • Khan A; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Yudi MB; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Nadir MA; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Majeed F; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Ali O; Heart and Vascular Center, Valley Health System, Winchester, Virginia.
  • Skiles J; Heart and Vascular Center, Valley Health System, Winchester, Virginia.
  • Bhim C; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Cohen M; Division of Cardiology, Westchester Medical Center, Valhalla, New York.
  • Lansman SL; Section of Cardiothoracic Surgery, Westchester Medical Center, Valhalla, New York.
  • Sharma SK; Division of Cardiology, Mount Sinai Health System, New York, New York.
  • Kini A; Division of Cardiology, Mount Sinai Health System, New York, New York.
J Interv Cardiol ; 31(6): 907-915, 2018 Dec.
Article en En | MEDLINE | ID: mdl-30168203
ABSTRACT

OBJECTIVES:

We report our multicenter experience on continuous hemodynamic monitoring using exclusively the steerable guide catheter (SGC) during MitraClip repair.

BACKGROUND:

Left atrial pressure (LAP) and V-wave are useful to evaluate MitraClip repair but no simple method of continuous monitoring exists.

METHODS:

From 11/2016 to 8/2017, 74 patients from four centers with symptomatic moderate-severe to severe mitral regurgitation (MR), underwent MitraClip NT repair with continuous hemodynamic monitoring via the SGC. Real-time LAP/V-wave changes were compared with transesophageal echocardiography (TEE). When mitral stenosis was suspected, transmitral gradients were verified by invasive hemodynamics. Clinical and echocardiographic outcomes were determined.

RESULTS:

Mean age was 78 ± 10 years and STS score 9.1 ± 11.0%. Pathology included leaflet prolapse/flail (45%), restriction (35%), and mixed (20%). Number of clips averaged 1.7 ± 0.7 per case. There was a significant reduction in LAP (21 ± 10 to 15 ± 7 mmHg, P < 0.0001) and V-wave(37 ± 19 to 24 ± 10 mmHg, P < 0.0001) post MitraClip, but the decrease was less in patients with atrial fibrillation (P < 0.05). Transmitral gradient significantly increased from 2.0 ± 1.2 to 4.0 ± 1.7 mmHg (P < 0.0001). Paradoxical increases in LAP and V-wave despite MR reduction were observed in three cases requiring MitraClip repositioning or retrieval to avoid stenosis. Follow-up averaged 5.0 ± 2.9 months and was 100% complete. KCCQ improvement was significant and MR reduction to <1+ was 67% and <2+ was 93% at 30 days.

CONCLUSIONS:

Continuous hemodynamic monitoring using the SGC complements TEE to assess and optimize MitraClip repair in real-time. Further validation is necessary but this feature may be part of future MitraClip and other transcatheter mitral repair systems.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cateterismo Cardíaco / Monitorización Hemodinámica / Válvula Mitral / Insuficiencia de la Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cateterismo Cardíaco / Monitorización Hemodinámica / Válvula Mitral / Insuficiencia de la Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article