Effect of Hybrid Kernel and Iterative Reconstruction on Objective and Subjective Analysis of Lung Nodule Calcification in Low-Dose Chest CT.
Hong, Seul Gi; Kang, Eun-Ju; Park, Jae Hyung; Choi, Won Jin; Lee, Ki-Nam; Kwon, Hee Jin; Ha, Dong-Ho; Kim, Dong Won; Kim, Sang Hyeon; Jo, Jeong-Hyun; Lee, Jongmin.
Afiliación
  • Hong SG; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Kang EJ; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Park JH; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Choi WJ; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Lee KN; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Kwon HJ; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Ha DH; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Kim DW; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Kim SH; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Jo JH; Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea.
  • Lee J; Department of Radiology, College of Medicine, Kyungpook National University, Daegu 41944, Korea.
Korean J Radiol ; 19(5): 888-896, 2018.
Article en En | MEDLINE | ID: mdl-30174478
Objective: To evaluate the differences in subjective calcification detection rates and objective calcium volumes in lung nodules according to different reconstruction methods using hybrid kernel (FC13-H) and iterative reconstruction (IR). Materials and Methods: Overall, 35 patients with small (< 4 mm) calcified pulmonary nodules on chest CT were included. Raw data were reconstructed using filtered back projection (FBP) or IR algorithm (AIDR-3D; Canon Medical Systems Corporation), with three types of reconstruction kernel: conventional lung kernel (FC55), FC13-H and conventional soft tissue kernel (FC13). The calcium volumes of pulmonary nodules were quantified using the modified Agatston scoring method. Two radiologists independently interpreted the role of each nodule calcification on the six types of reconstructed images (FC55/FBP, FC55/AIDR-3D, FC13-H/FBP, FC13-H/AIDR-3D, FC13/FBP, and FC13/AIDR-3D). Results: Seventy-eight calcified nodules detected on FC55/FBP images were regarded as reference standards. The calcium detection rates of FC55/AIDR-3D, FC13-H/FBP, FC13-H/AIDR-3D, FC13/FBP, and FC13/AIDR-3D protocols were 80.7%, 15.4%, 6.4%, 52.6%, and 28.2%, respectively, and FC13-H/AIDR-3D showed the smallest calcium detection rate. The calcium volume varied significantly with reconstruction protocols and FC13/AIDR-3D showed the smallest calcium volume (0.04 ± 0.22 mm3), followed by FC13-H/AIDR-3D. Conclusion: Hybrid kernel and IR influence subjective detection and objective measurement of calcium in lung nodules, particularly when both techniques (FC13-H/AIDR-3D) are combined.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Calcinosis / Tomografía Computarizada por Rayos X / Nódulos Pulmonares Múltiples Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Calcinosis / Tomografía Computarizada por Rayos X / Nódulos Pulmonares Múltiples Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article