Your browser doesn't support javascript.
loading
Shear wave elastography of the cervical arteries: A novel approach to the assessment of cervical arterial wall stiffness. An investigation of psychometric properties and intra-rater reliability.
Thomas, Lucy; Low, Juanita; Chan, Kalos; Durbridge, Gail.
Afiliación
  • Thomas L; School of Health and Rehabilitation Sciences, University of Queensland, Australia. Electronic address: l.thomas2@uq.edu.au.
  • Low J; School of Health and Rehabilitation Sciences, University of Queensland, Australia.
  • Chan K; School of Health and Rehabilitation Sciences, University of Queensland, Australia.
  • Durbridge G; Centre for Advanced Imaging, University of Queensland, Australia.
Musculoskelet Sci Pract ; 40: 96-100, 2019 04.
Article en En | MEDLINE | ID: mdl-30262424
ABSTRACT

BACKGROUND:

Cervical arterial dissection, can occur spontaneously and is a rare but catastrophic adverse event associated with neck manipulation. Pathophysiology involves altered integrity of the arterial wall increasing its vulnerability to minor trauma. Those at risk are difficult to detect. Previous screening investigated blood flow but altered mechanical properties as stiffness of cervical arterial wall could provide a more valid indication of arterial integrity or even early dissection.

OBJECTIVES:

To investigate suitability and intra-rater reliability of shear wave ultrasound elastography to measure mechanical properties of the cervical arterial wall. Suitability was assessed by ability to track arteries along their length and measurement accuracy.

DESIGN:

Observational and intra-rater reliability study.

METHODS:

Internal carotid (ICA) and vertebral arteries (VA) of healthy participants were examined with shear wave elastography. Shear wave velocity (m/s) indicative of wall stiffness was measured with the head in the neutral position proximally (C3-4) and distally (C1-2) where injuries have been more commonly reported. Proximal measures were repeated to assess intra-rater reliability.

RESULTS:

Thirty healthy participants (13 female), mean age of 29 (±12.8) years were imaged. Mean VA wall stiffness (3.4 m/s) was greater than ICA (2.3 m/s) (p < 0.000). Intra-rater reliability for ICA was ICC 0.81 (CI 0.52 to 0.92) and for VA ICC 0.76 (CI 0.38 to 0.9). Standard error of measurement was 0.16 for ICA and 0.34 for VA.

CONCLUSIONS:

Shear wave ultrasound elastography appears a suitable and reliable method to measure cervical arterial wall stiffness, justifying further research into its use for screening arterial integrity.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vértebras Cervicales / Módulo de Elasticidad / Rigidez Vascular Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Musculoskelet Sci Pract Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vértebras Cervicales / Módulo de Elasticidad / Rigidez Vascular Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Musculoskelet Sci Pract Año: 2019 Tipo del documento: Article