Your browser doesn't support javascript.
loading
Gasless transoral endoscopic thyroidectomy vestibular approach (gasless TOETVA).
Park, Jun-Ook; Park, Yeong Jun; Kim, Mi Ra; Sun, Dong-Il; Kim, Min-Sik; Koh, Yoon Woo.
Afiliación
  • Park JO; Department of Otolaryngology-Head and Neck Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Park YJ; Department of Otolaryngology Head and Neck Surgery, Inje University College of Medicine, Busan, Republic of Korea.
  • Kim MR; Department of Otolaryngology Head and Neck Surgery, Inje University College of Medicine, Busan, Republic of Korea.
  • Sun DI; Department of Otolaryngology-Head and Neck Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Kim MS; Department of Otolaryngology-Head and Neck Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Koh YW; Department of Otorhinolaryngology, Yonsei University Colloge of Medicine, Severance Hospital, Yonsei University Health System, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Republic of Korea. ywkohent@yuhs.ac.
Surg Endosc ; 33(9): 3034-3039, 2019 09.
Article en En | MEDLINE | ID: mdl-31087173
ABSTRACT

BACKGROUND:

The transoral endoscopic thyroidectomy vestibular approach (TOETVA) has been the subject of increasing interest from several institutions around the world over the last 2 years. Recently, we successfully performed TOETVA in live human patients without CO2 gas using our newly designed retractable blade.

METHODS:

We reviewed the medical records of 15 consecutive patients who underwent gasless TOETVA using a self-retaining retractor.

RESULTS:

We successfully performed 13 thyroid lobectomies and 2 total thyroidectomies in 15 patients. No patient exhibited serious postoperative complications such as recurrent laryngeal nerve palsy and permanent hypocalcemia. One patient developed transient hypocalcemia but recovered within 2 months. No patient developed a wound infection; furthermore, no visible scar or dimpling was evident on the neck of any patient.

CONCLUSION:

Gasless TOETVA provides enough working space and good visibility to perform thyroid surgery without any risk of CO2 gas-related complications.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Enfermedades de la Tiroides / Glándula Tiroides / Tiroidectomía / Parálisis de los Pliegues Vocales / Cicatriz / Cirugía Endoscópica por Orificios Naturales / Hipocalcemia Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Enfermedades de la Tiroides / Glándula Tiroides / Tiroidectomía / Parálisis de los Pliegues Vocales / Cicatriz / Cirugía Endoscópica por Orificios Naturales / Hipocalcemia Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2019 Tipo del documento: Article