Your browser doesn't support javascript.
loading
Comment on "Isochoric, isobaric, and ultrafast conductivities of aluminum, lithium, and carbon in the warm dense matter regime".
Witte, B B L; Röpke, G; Neumayer, P; French, M; Sperling, P; Recoules, V; Glenzer, S H; Redmer, R.
Afiliación
  • Witte BBL; Institut für Physik, Universität Rostock, 18051 Rostock, Germany.
  • Röpke G; SLAC National Accelerator Laboratory, 2575 Sand Hill Road, MS 72 Menlo Park, California 94025, USA.
  • Neumayer P; Institut für Physik, Universität Rostock, 18051 Rostock, Germany.
  • French M; Extreme Matter Institute, GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, 64291 Darmstadt, Germany.
  • Sperling P; Institut für Physik, Universität Rostock, 18051 Rostock, Germany.
  • Recoules V; SLAC National Accelerator Laboratory, 2575 Sand Hill Road, MS 72 Menlo Park, California 94025, USA.
  • Glenzer SH; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Redmer R; Aible GmbH, Am Vögenteich 24, 18055 Rostock, Germany.
Phys Rev E ; 99(4-2): 047201, 2019 Apr.
Article en En | MEDLINE | ID: mdl-31108609
ABSTRACT
Dharma-wardana et al. [M. W. C. Dharma-wardana et al., Phys. Rev. E 96, 053206 (2017)2470-004510.1103/PhysRevE.96.053206] recently calculated dynamic electrical conductivities for warm dense matter as well as for nonequilibrium two-temperature states termed "ultrafast matter" (UFM) [M. W. C. Dharma-wardana, Phys. Rev. E 93, 063205 (2016)2470-004510.1103/PhysRevE.93.063205]. In this Comment we present two evident reasons why these UFM calculations are neither suited to calculate dynamic conductivities nor x-ray Thomson scattering spectra in isochorically heated warm dense aluminum. First, the ion-ion structure factor, a major input into the conductivity and scattering spectra calculations, deviates strongly from that of isochorically heated aluminum. Second, the dynamic conductivity does not show a non-Drude behavior which is an essential prerequisite for a correct description of the absorption behavior in aluminum. Additionally, we clarify misinterpretations by Dharma-wardana et al. concerning the conductivity measurements of Gathers [G. R. Gathers, Int. J. Thermophys. 4, 209 (1983)IJTHDY0195-928X10.1007/BF00502353].

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Phys Rev E Año: 2019 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Phys Rev E Año: 2019 Tipo del documento: Article País de afiliación: Alemania