Your browser doesn't support javascript.
loading
Ex Vivo Biomechanical Comparison of Titanium Locking Plate, Stainless Steel Nonlocking Plate, and Tie-in External Fixator Applied by a Dorsal Approach on Ostectomized Humeri of Pigeons (Columba livia).
Darrow, Brett G; Weigel, Joseph P; Greenacre, Cheryl B; Xie, Xie; Liaw, Peter K; Biskup, Jeffery J.
Afiliación
  • Darrow BG; Small Animal Clinical Sciences, The University of Tennessee College of Veterinary Medicine, Knoxville, TN 37996, USA.
  • Weigel JP; Small Animal Clinical Sciences, The University of Tennessee College of Veterinary Medicine, Knoxville, TN 37996, USA.
  • Greenacre CB; Small Animal Clinical Sciences, The University of Tennessee College of Veterinary Medicine, Knoxville, TN 37996, USA.
  • Xie X; Departments of Materials Science and Engineering, The University of Tennessee College of Engineering, Knoxville, TN 37996, USA.
  • Liaw PK; Departments of Materials Science and Engineering, The University of Tennessee College of Engineering, Knoxville, TN 37996, USA.
  • Biskup JJ; Small Animal Clinical Sciences, The University of Tennessee College of Veterinary Medicine, Knoxville, TN 37996, USA.
J Avian Med Surg ; 33(1): 29-37, 2019 03 01.
Article en En | MEDLINE | ID: mdl-31124609
ABSTRACT
To compare the bending strength of a locking plate (LP), nonlocking plate (NLP), and an external skeletal fixator intramedullary pin (ESF-IM) tie-in fixation applied by a dorsal approach in an avian humerus fracture model, 5 left humeri obtained from pigeon (Columba livia) cadavers were randomly assigned to each repair technique (n = 15). The ESF-IM group was repaired with a 0.062-inch intramedullary pin tied-in with two 0.035-inch positive profile transfixation pins using acrylic filled plastic tubing. The LP group was repaired with a dorsally applied titanium 1.6-mm screw 7-hole locking plate (1 bicortical and 2 monocortical screws in each segment). The NLP group was repaired with a dorsally applied 6-hole stainless steel 1.5-mm dynamic compression plate (all bicortical screws). All constructs were applied before complete ostectomy to allow perfect reconstruction. Constructs were cyclically tested nondestructively for 1000 cycles in four-point bending before being tested to failure. Outcome measures included stiffness, strength, and strain energy. All specimens cycled without failure. The ESF-IM specimens were significantly stiffer and stronger than the plated repair groups. Plated constructs had significantly higher strain energies than ESF-IM. LP and NLP were of equal stiffness, strength, and strain energies. This study demonstrated that bending biomechanical properties of the ESF-IM configuration were superior to those of the dorsal plate fixation. Exact properties of fixation required to facilitate avian fracture healing are largely unknown. Further study, including assessments of optimal plate position and configuration, and torsional and in vivo studies in avian species are warranted.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Columbidae / Placas Óseas / Fracturas Óseas / Fijación de Fractura / Húmero Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: J Avian Med Surg Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Columbidae / Placas Óseas / Fracturas Óseas / Fijación de Fractura / Húmero Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: J Avian Med Surg Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos