Inkjet printed microfluidic paper-based analytical device (µPAD) for glucose colorimetric detection in artificial urine.
Zhang, Han; Smith, Ethan; Zhang, Wei; Zhou, Anhong.
Afiliación
  • Zhang H; Department of Biological Engineering, Utah State University, 4105 Old Main Hill, Logan, UT, 84322-4105, USA.
  • Smith E; Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
  • Zhang W; Department of Biological Engineering, Utah State University, 4105 Old Main Hill, Logan, UT, 84322-4105, USA.
  • Zhou A; Department of Biological Engineering, Utah State University, 4105 Old Main Hill, Logan, UT, 84322-4105, USA. Anhong.Zhou@usu.edu.
Biomed Microdevices ; 21(3): 48, 2019 06 10.
Article en En | MEDLINE | ID: mdl-31183565
ABSTRACT
This article introduces a novel inkjet printing method for the fabrication of a microfluidic paper-based analytical device (µPADs) with improved analytical performance for colorimetric measurements. Firstly, a hydrophobic boundary was created by wax printing on chromatography paper. Then, chitosan (CHI), 3,3',5,5'-Tetramethylbenzidine (TMB) and enzymatic mixture solvent (glucose oxidase (GOx) and horseradish peroxidase (HRP)) were sequentially printed in the sensing zone. Polyethylene glycol (PEG6000) was mixed with the bienzymatic solution to act as an enzyme stabilizer, forming the printable ink. The resulting µPADs exhibited a linear relationship between color intensity and glucose concentration from 0.0 25 mg/ml to 0 .5mg/ml. The detectable glucose concentration was in a clinically relevant range from 0.01 mg/ml to 4 mg/ml. The limit of detection (LOD) was achieved at 0.01 mg/ml. After 60-day storage under 4 °C, the color intensity at the testing zone retained over 80% of the original intensity. In addition, a smartphone application was developed for in situ colorimetric image processing, and the colorimetric analysis results were compared with those from the use of a scanner followed by processing using ImageJ. Furthermore, the development of this ink printing method also provides a point of care (POC) platform for other substances detection purposes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Papel / Impresión / Urinálisis / Colorimetría / Dispositivos Laboratorio en un Chip / Glucosa / Tinta Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biomed Microdevices Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Papel / Impresión / Urinálisis / Colorimetría / Dispositivos Laboratorio en un Chip / Glucosa / Tinta Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biomed Microdevices Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos