Your browser doesn't support javascript.
loading
A combined LC-MS/MS and LC-MS3 multi-method for the quantification of iodothyronines in human blood serum.
Richards, Keith H; Monk, Ray; Renko, Kostja; Rathmann, Daniel; Rijntjes, Eddy; Köhrle, Josef.
Afiliación
  • Richards KH; Institut für Experimentelle Endokrinologie, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Monk R; Institut für Experimentelle Endokrinologie, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Renko K; Institut für Experimentelle Endokrinologie, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Rathmann D; Department of Analytical Chemistry, A. Menarini Research & Business Service GmbH, Glienicker Weg 125, 12489, Berlin, Germany.
  • Rijntjes E; Institut für Experimentelle Endokrinologie, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
  • Köhrle J; Institut für Experimentelle Endokrinologie, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. josef.koehrle@charite.de.
Anal Bioanal Chem ; 411(21): 5605-5616, 2019 Aug.
Article en En | MEDLINE | ID: mdl-31201460
ABSTRACT
We report here a novel approach for the extraction and analysis of thyroid hormones (TH) and their metabolites (THM) from human serum samples. Our method features a compact, 96-well micro-titre plate-based pre-analytic extraction/clean-up workflow combined with an isotope dilution LC-MS/MS-MS3 analytical method. In particular, these features make possible the detection of iodothyronines at their endogenous concentrations in serum differing by a factor of ca. 104, with potential to semi-automate the pre-analytics. The method was validated by the assessment of linearity, lower limits of quantification and detection (LLOQ and LLOD respectively), intra- and inter-day accuracy, precision, process efficiency (PE), matrix effect (ME) and relative recovery (RE). Calibration curves were linear in the concentration range in sample matrix from 0.1-250 nM for T3, rT3, T4 and 3-T1AM and from 0.005-1 nM for 3,5-T2 and 3,3'-T2. Using a 200-µL sample volume, the analyte dependant LLOQ were in the range 0.005 (3,5-T2) to 0.25 (T4) nM and LLOD were between 0.002 (3,5-T2) and 0.052 nM (T4). We applied the LC-MS/MS-MS3 method to the analysis of a cross section of patients with disorders of the thyroid hormone axis. T4, T3 and rT3 concentrations (± standard deviation) were 120 ± 18, 1.9 ± 0.4 and 0.45 ± 0.09 nM respectively. 3,3'-T2 concentrations (± standard deviation) were 0.079 ± 0.022 nM; 3,5-T2 concentrations were below the LLOQ and/or LLOD in all but a single sample (0.013 nM). This method expands the analytical spectrum to endogenous thyroid hormone metabolites such as 3,5-T2 which exert biological actions and rT3 which may act as surrogate markers for disturbed thyroid hormone metabolism. Graphical abstract.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tironinas / Cromatografía Liquida / Espectrometría de Masas en Tándem Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2019 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tironinas / Cromatografía Liquida / Espectrometría de Masas en Tándem Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2019 Tipo del documento: Article País de afiliación: Alemania