Your browser doesn't support javascript.
loading
[Determination of methyl ethyl ketone in urine by headspace gas chromatography].
Zhang, M P; Yu, Z G; Sun, Y X; Wang, C J; Liu, Z; Wei, H Y; Zou, W.
Afiliación
  • Zhang MP; Shandong Academy of Occupational Health and Occupational Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Yu ZG; Jinan Center For Disease Control and Prevention, Jinan 250012, China.
  • Sun YX; Shandong Academy of Occupational Health and Occupational Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Wang CJ; Shandong Academy of Occupational Health and Occupational Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Liu Z; Jinan Center For Disease Control and Prevention, Jinan 250012, China.
  • Wei HY; Shandong Academy of Occupational Health and Occupational Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Zou W; Shandong Academy of Occupational Health and Occupational Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
Article en Zh | MEDLINE | ID: mdl-31256531
ABSTRACT

Objective:

To establish a method for determination of methyl ethyl ketone in urine by headspace gas chromatography.

Methods:

In the urine sample(hereinafter referred to as urine sample), methyl ethyl ketone is pretreated by headspace technology, and a certain amount of head air is injected into the gas chromatograph, separated by capillary column, detected by hydrogen flame ionization detector, and the retention time is qualitative and the peak height is high. Peak area.

Results:

Good linearity was in the range of 0.01 to 6.0 µg/ml with a regression equation of y=13.316x+0.8497 and γ=0.9997.The minimum detectable concentration of methyl ethyl ketone was 0.01 µg/ml. The range intra-day RSD and inter-day RSD were 2.2%-5.5% and 2.5%-6.1% respectively. Urine samples can be stored for 20 days in the refrigerator at 4 ℃.

Conclusion:

The method has a high advantage of sensitivity and accuracy, and also easy to operate. Therefore, it is suitable for the determination of methyl ethyl ketone in urine.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cromatografía de Gases Tipo de estudio: Qualitative_research Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cromatografía de Gases Tipo de estudio: Qualitative_research Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2019 Tipo del documento: Article País de afiliación: China