Your browser doesn't support javascript.
loading
Detection of hepatic steatosis and iron content at 3 Tesla: comparison of two-point Dixon, quantitative multi-echo Dixon, and MR spectroscopy.
Zhan, Chenyang; Olsen, Sonja; Zhang, Hoi Cheung; Kannengiesser, Stephan; Chandarana, Hersh; Shanbhogue, Krishna Prasad.
Afiliación
  • Zhan C; Department of Radiology, NYU Langone Health, 660 First Ave, New York, NY, 10016, USA.
  • Olsen S; Department of Hepatology, NYU Langone Health, New York, NY, USA.
  • Zhang HC; Department of Radiology, NYU Langone Health, 660 First Ave, New York, NY, 10016, USA.
  • Kannengiesser S; Siemens Healthcare, Erlangen, Germany.
  • Chandarana H; Department of Radiology, NYU Langone Health, 660 First Ave, New York, NY, 10016, USA.
  • Shanbhogue KP; Department of Radiology, NYU Langone Health, 660 First Ave, New York, NY, 10016, USA. Krishna.Shanbhogue@nyulangone.org.
Abdom Radiol (NY) ; 44(9): 3040-3048, 2019 09.
Article en En | MEDLINE | ID: mdl-31286208
ABSTRACT

PURPOSE:

To compare qualitative results obtained from computer-aided dual-ratio analysis on T1-weighted two-point Dixon, with T2*-corrected multi-echo Dixon and T2-corrected multi-echo single-voxel MR spectroscopy sequence (MRS) for evaluation of liver fat and iron at 3T. METHODS AND MATERIALS This retrospective, HIPAA-compliant, IRB-approved study included 479 patients with known or suspected liver disease. Two-point Dixon, multi-echo Dixon, and MR spectroscopy sequences were performed for each patient at 3T. A receiver-operating characteristic analysis was performed to compare the diagnostic performance in 80 patients using biopsy as the standard. Sensitivity, specificity, PPV, and NPV of qualitative two-point Dixon results, multi-echo Dixon (PDFF and R2*), and MRS (fat fraction and R2 water) for detection of hepatic steatosis and siderosis were assessed.

RESULTS:

Fat fractions obtained from MRS and multi-echo Dixon have equivalent accuracy for detection of hepatic steatosis (AUC, sensitivity and specificity 0.90 vs 0.88, 0.77 vs. 0.82, and 0.90 vs. 0.82), but the optimal cutoff value is higher for MRS (6.05% vs. 3.4%). The dual-ratio Dixon discrimination technique showed high negative predictive value for detection of hepatic steatosis and siderosis (0.90 and 0.94, respectively). R2* from multi-echo Dixon and R2water from MRS have equivalent accuracy for detection of iron overload at 3T (AUC 0.89 vs. 0.88). The optimal cutoff for R2* and R2water are 60.5 s-1 and 40.85 s-1, respectively.

CONCLUSION:

The computer-aided dual-ratio discrimination with two-point Dixon is a useful qualitative screening tool with high negative predictive value for hepatic steatosis and iron overload. Multi-echo Dixon and MRS have similar accuracy for detection of hepatic steatosis and iron overload at 3 Tesla.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Espectroscopía de Resonancia Magnética / Sobrecarga de Hierro / Hígado Graso Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Abdom Radiol (NY) Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Espectroscopía de Resonancia Magnética / Sobrecarga de Hierro / Hígado Graso Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Abdom Radiol (NY) Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos