Your browser doesn't support javascript.
loading
Effects of gender and defect reversibility on detection of coronary disease with an upright and supine cadmium-zinc-telluride camera.
Athar, Muhammad W; Waqar, Fahad; Dwivedi, Alok K; Ahmad, Saad; Sanghvi, Saagar; Scott, Elonia; Khan, Naseer; Gerson, Myron C.
Afiliación
  • Athar MW; Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati College of Medicine, 231 Albert B. Sabin Way ML 0542, Cincinnati, OH, 45267-0542, USA.
  • Waqar F; Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati College of Medicine, 231 Albert B. Sabin Way ML 0542, Cincinnati, OH, 45267-0542, USA.
  • Dwivedi AK; Division of Biostatistics and Epidemiology, Department of Molecular and Translational Medicine, Paul L. Foster School of Medicine, Texas Tech University Health Sciences Center El Paso, El Paso, TX, USA.
  • Ahmad S; Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati College of Medicine, 231 Albert B. Sabin Way ML 0542, Cincinnati, OH, 45267-0542, USA.
  • Sanghvi S; Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
  • Scott E; Division of Nuclear Medicine, Department of Radiology, University of Cincinnati Medical Center, Cincinnati, OH, USA.
  • Khan N; Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati College of Medicine, 231 Albert B. Sabin Way ML 0542, Cincinnati, OH, 45267-0542, USA.
  • Gerson MC; Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati College of Medicine, 231 Albert B. Sabin Way ML 0542, Cincinnati, OH, 45267-0542, USA. myron.gerson@uc.edu.
J Nucl Cardiol ; 28(4): 1569-1582, 2021 08.
Article en En | MEDLINE | ID: mdl-31489586
ABSTRACT

BACKGROUND:

Limited data address the roles of gender, perfusion defect reversibility, and imaging position in interpretation of images acquired on an upright/supine cadmium-zinc-telluride (CZT) cardiac imaging system. METHODS AND

RESULTS:

From a consecutive cohort of patients imaged on an upright/supine CZT camera, 260 patients with coronary angiograms were studied. Multivariable models identified gender as a significant effect modifier for imaging variables of CAD. For males, a supine summed stress score (SSS) ≥ 3 provided high accuracy (sensitivity 70.7%, specificity 72.2%), and highest contribution to multivariable models. In females, supine SSS ≥ 2 provided the best cut-off for defect size and severity (sensitivity 90%, specificity 35.9%), but specificity was improved substantially to 53.3% with decrease in sensitivity to 80% by also requiring quantitative identification of perfusion defect reversibility in the supine position. Eight variables, accurate for predicting coronary disease, were more accurate with supine than upright imaging.

CONCLUSIONS:

Perfusion defect reversibility improved specificity in female patients for detection of coronary disease compared to perfusion defect size and extent alone. Supine images provided superior accuracy for detection of coronary disease compared to upright images.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Telurio / Zinc / Enfermedad de la Arteria Coronaria / Cadmio / Cámaras gamma / Tomografía Computarizada de Emisión de Fotón Único / Imagen de Perfusión Miocárdica / Posicionamiento del Paciente Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Telurio / Zinc / Enfermedad de la Arteria Coronaria / Cadmio / Cámaras gamma / Tomografía Computarizada de Emisión de Fotón Único / Imagen de Perfusión Miocárdica / Posicionamiento del Paciente Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos