Background suppressed magnetization transfer MRI.
van Gelderen, Peter; Duyn, Jeff H.
Afiliación
  • van Gelderen P; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland.
  • Duyn JH; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland.
Magn Reson Med ; 83(3): 883-891, 2020 03.
Article en En | MEDLINE | ID: mdl-31502706
ABSTRACT

PURPOSE:

Up to 30% of the hydrogen atoms in brain tissue are part of molecules ("semisolids") other than water. In MRI, their magnetization is typically not observed directly, but can influence the water magnetization through magnetization transfer (MT). Comparison of MRI scans differentially sensitized to MT allows estimation of the semisolid fraction and potential changes with disease. Here, we present an approach designed to improve this estimate by measuring the size of the MT effect in a single scan.

METHODS:

A stimulated echo sequence was used to generate a spatial pattern in the longitudinal water magnetization, which was then given time to exchange with semisolids. After saturating the remaining water magnetization, reverse exchange was allowed to partly re-establish the original water magnetization pattern. The third excitation pulse then formed a stimulated echo out of this pattern.

RESULTS:

MT data were obtained on 10 human subjects at 7 T with varying exchange times. The images showed the expected time dependence of signal associated with the forward and reverse exchange processes. Excellent suppression of non-exchanging background signal was achieved. As expected, this suppression came at the price of a substantial reduction in exchange-related signal (by ~75% compared to the signal in saturation recovery MT), in part because of the reliance on a 2-step exchange process.

CONCLUSION:

The results demonstrate an MT signal can be observed in a single acquisition without subtraction. This may be advantageous for MT measurements when signal instabilities related to motion and physiological variations exceed thermal noise sources.