Your browser doesn't support javascript.
loading
Effect of long-term frozen storage and thawing of stool samples on faecal haemoglobin concentration and diagnostic performance of faecal immunochemical tests.
Gies, Anton; Niedermaier, Tobias; Weigl, Korbinian; Schrotz-King, Petra; Hoffmeister, Michael; Brenner, Hermann.
Afiliación
  • Gies A; Division of Preventive Oncology, German Cancer Research Center (DKFZ) and National Center for Tumor Diseases (NCT), Im Neuenheimer Feld 460, 69120 Heidelberg, Germany, Phone: +49-6221-42-3032, Fax: +49-6221-56-5231.
  • Niedermaier T; Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Weigl K; Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Schrotz-King P; German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Hoffmeister M; Division of Preventive Oncology, German Cancer Research Center (DKFZ) and National Center for Tumor Diseases (NCT), Heidelberg, Germany.
  • Brenner H; Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany.
Clin Chem Lab Med ; 58(3): 390-398, 2020 02 25.
Article en En | MEDLINE | ID: mdl-31655793
ABSTRACT
Background Faecal samples collected and stored frozen over years may be a valuable resource for efficient retrospective evaluation of faecal immunochemical tests (FITs). We aimed to assess how prolonged frozen storage and freeze-thaw cycles might affect measures of faecal haemoglobin (Hb) and diagnostic performance of FITs. Methods From 2005 through 2010, participants of screening colonoscopy (n = 2042) and clinical colorectal cancer (CRC) cases (n = 184) provided faecal samples in stool containers (60 mL). The samples were stored at -80 °C for up to 11 years and underwent three freeze-thaw cycles. Between each cycle, a defined amount of faeces was extracted using the manufacturer's sampling device of one or two FITs (RIDASCREEN, OC-Sensor). Faecal Hb concentration and diagnostic performance were calculated and compared across freeze-thaw cycles. Results For RIDASCREEN and the OC-Sensor, repeat measurements were available for 504 and 551 study participants, respectively. Hb concentrations correlated strongly (0.77 and 0.85, respectively) and diagnostic performance indicators were similar at the repeat measurements among the same FITs. For RIDASCREEN we found even slightly higher Hb levels, sensitivities and area under the curves (AUCs) after the third than after the first freeze-thaw cycle. For the OC-Sensor the Hb levels, sensitivities and AUCs were slightly lower after prolonged storage and one additional freeze-thaw cycle. Conclusions Measures of Hb and diagnostic performance were fairly stable, even after long-term frozen storage and multiple freeze-thaw cycles of raw faecal samples. Faecal samples collected in prospective screening studies and kept frozen at -80 °C before analysis seem useful for timely and efficient retrospective evaluation of FIT performance.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hemoglobinas / Inmunoquímica / Criopreservación / Heces Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hemoglobinas / Inmunoquímica / Criopreservación / Heces Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2020 Tipo del documento: Article