Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis: Data From a Nationwide Analysis.
Circulation
; 141(4): 260-268, 2020 01 28.
Article
en En
| MEDLINE
| ID: mdl-31736332
ABSTRACT
BACKGROUND:
Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices.METHODS:
Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France.RESULTS:
A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10-599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P=0.005), cardiovascular death (relative risk, 0.82; corrected P=0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P<0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P<0.0001).CONCLUSIONS:
On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Estenosis de la Válvula Aórtica
/
Marcapaso Artificial
/
Bases de Datos Factuales
/
Reemplazo de la Válvula Aórtica Transcatéter
Tipo de estudio:
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
País/Región como asunto:
Europa
Idioma:
En
Revista:
Circulation
Año:
2020
Tipo del documento:
Article
País de afiliación:
Francia