Your browser doesn't support javascript.
loading
Nitrogen, phosphorus and sulfur tri-doped carbon dots are specific and sensitive fluorescent probes for determination of chromium(VI) in water samples and in living cells.
Huang, Shan; Yang, Erli; Yao, Jiandong; Chu, Xu; Liu, Yi; Xiao, Qi.
Afiliación
  • Huang S; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China.
  • Yang E; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China.
  • Yao J; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China.
  • Chu X; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China.
  • Liu Y; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China.
  • Xiao Q; Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, College of Chemistry and Materials, Nanning Normal University, Nanning, 530001, People's Republic of China. qi.xiao@whu.edu.cn.
Mikrochim Acta ; 186(12): 851, 2019 11 27.
Article en En | MEDLINE | ID: mdl-31776683
ABSTRACT
A rapid, sensitive, and selective fluorometric assay is described for the determination of chromium(VI) in real waters and living cells. The method is making use of nitrogen, phosphorus, and sulfur tri-doped carbon dots (NPS-CDs) which have absorption/emission maxima at 360/505 nm/nm. Cr(VI) has an absorption maximum at 350 nm and causes an inner filter effect (IFE) on the blue fluorescence of the NPS-CDs. The NPS-CDs were hydrothermally synthesized using p-aminobenzenesulfonic acid and tetrakis(hydroxymethyl)phosphonium chloride as precursors. The NPS-CDs were characterized by transmission electron microscopy, X-ray diffraction, and several spectroscopic methods. They are biocompatible and negligibly cytotoxic when tested with HeLa cells and MCF-7 cells even after 48 h of incubation. The NPS-CDs were used as fluorescent probes for Cr(VI). The detection limit is 0.23 µM (three times standard deviation versus slope), and the linear response covers the 1 to 500 µM chromate concentration range. The NPS-CDs were applied to the determination of Cr(VI) in real waters and living cells (HeLa and MCF-7) and gave satisfying results. Graphical abstractSchematic representation of hydrothermal synthesis of nitrogen, phosphorus, and sulfur tri-doped carbon dots (NPS-CDs) for Cr(VI) detection via inner filter effect (IFE). NPS-CDs were applied to the determination of Cr(VI) in living cells (HeLa and MCF-7) with satisfying results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Cromo / Puntos Cuánticos / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Cromo / Puntos Cuánticos / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2019 Tipo del documento: Article