Your browser doesn't support javascript.
loading
Stability and bioactivity of pepCD47 attachment on stainless steel surfaces.
Inamdar, Vaishali V; Fitzpatrick, Emmett; Alferiev, Ivan; Nagaswami, Chandrasekaran; Spruce, Lynn A; Fazelinia, Hossein; Bratinov, George; Seeholzer, Steven H; Levy, Robert J; Fishbein, Ilia; Stachelek, Stanley J.
Afiliación
  • Inamdar VV; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States.
  • Fitzpatrick E; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States.
  • Alferiev I; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States; The Proteomics Core Facility, The Children's Hospital of Philadelphia, Research Insititute, United States.
  • Nagaswami C; Perelman School of Medicine, The University of Pennsylvania, United States; Department of Cell and Developmental Biology, Perelman School of Medicine, The University of Pennsylvania, United States.
  • Spruce LA; The Proteomics Core Facility, The Children's Hospital of Philadelphia, Research Insititute, United States.
  • Fazelinia H; The Proteomics Core Facility, The Children's Hospital of Philadelphia, Research Insititute, United States.
  • Bratinov G; Division of Orthopedics-Department of Pediatrics, The Children's Hospital of Philadelphia, United States.
  • Seeholzer SH; The Proteomics Core Facility, The Children's Hospital of Philadelphia, Research Insititute, United States.
  • Levy RJ; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States; Perelman School of Medicine, The University of Pennsylvania, United States.
  • Fishbein I; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States; Perelman School of Medicine, The University of Pennsylvania, United States. Electronic address: fishbein@email.chop.edu.
  • Stachelek SJ; Division of Cardiology-Department of Pediatrics, The Children's Hospital of Philadelphia, United States; Perelman School of Medicine, The University of Pennsylvania, United States. Electronic address: stachelek@email.chop.edu.
Acta Biomater ; 104: 231-240, 2020 03 01.
Article en En | MEDLINE | ID: mdl-31935523
ABSTRACT
In-stent restenosis (ISR) and late stent thrombosis are the major complications associated with the use of metal stents and drug eluting stents respectively. Our lab previously investigated the use of peptide CD47 in improving biocompatibility of bare metal stents in a rat carotid stent model and our results demonstrated a significant reduction in platelet deposition and ISR. However, this study did not characterize the stability of the pepCD47 on metal surfaces post storage, sterilization and deployment. Thus, the objective of the present study was 1) to test the stability of the peptide post - storage, sterilization, exposure to shear and mechanical stress and 2) to begin to expand our current knowledge of pepCD47 coated metal surfaces into the preclinical large animal rabbit model. Our results show that the maximum immobilization density of pepCD47 on metal surfaces is approximately 350 ng/cm2. 100% of the pepCD47 was retained on the metal surface post 24 weeks of storage at 4 °C, exposure to physiological shear stress, and mechanical stress of stent expansion. The bioactivity of the pepCD47 was found to be intact post 24 weeks of storage and ethylene oxide sterilization. Finally our ex vivo studies demonstrated that compared to bare metal the rabbit pepCD47 coated surfaces showed - 45% reduced platelet adhesion, a 10-fold decrease in platelet activation, and 93% endothelial cell retention. Thus, our data suggests that pepCD47 coating on metal surfaces is stable and rabbit pepCD47 shows promising preliminary results in preventing thrombosis and not inhibiting the growth of endothelial cells. STATEMENT OF

SIGNIFICANCE:

Biocompatibility of bare metal stents is a major challenge owing to the significantly high rates of in-stent restenosis. Previously we demonstrated that peptide CD47 functionalization improves the biocompatibility of bare metal stents in rat model. A similar trend was observed in our ex vivo studies where rabbit blood was perfused over the rabbit pepCD47 functionalized surfaces. These results provide valuable proof of concept data for future in vivo rabbit model studies. In addition, we investigated stability of the pepCD47 on metal surface and observed that pepCD47 coating is stable over time and resistant to industrially relevant pragmatic challenges.