Your browser doesn't support javascript.
loading
Punching a Graft for Descemet Membrane Endothelial Keratoplasty Onto a Contact Lens Reduces Endothelial Cell Loss at the Graft's Margin.
Achiron, Asaf; Nahum, Yoav; Adler, Avital; Nisgav, Yael; Bahar, Irit; Livny, Eitan.
Afiliación
  • Achiron A; Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel.
  • Nahum Y; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Adler A; Department of Ophthalmology, Edith Wolfson Medical Center, Holon, Israel; and.
  • Nisgav Y; Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel.
  • Bahar I; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Livny E; Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel.
Cornea ; 39(8): 1027-1030, 2020 Aug.
Article en En | MEDLINE | ID: mdl-32384303
ABSTRACT

PURPOSE:

To evaluate whether punching Descemet membrane endothelial keratoplasty (DMEK) corneal grafts onto a contact lens scaffold reduces endothelial cell loss at the graft margin in comparison to punching the graft directly onto the donor stroma.

METHODS:

DMEK grafts were prepared using 2 different methods after peeling the graft from the stroma punching onto a contact lens and punching onto the donor stroma. The grafts were then evaluated for the width of Descemet membrane devoid of endothelial cells in the peripheral ring, measured at 4 points at the graft margin.

RESULTS:

Our study included 6 grafts, harvested from 3 donors aged 66.3 ± 5.1 years. Grafts prepared on a contact lens scaffolding had more of their Descemet membrane margin populated by endothelial cells than did grafts that were punched directly onto the donor stroma (total denuded area 0.06 ± 0.08 mm vs. 1.17 ± 0.02 mm, P = 0.018; maximal width of denuded area 59.6 ± 28.4 µm vs. 100.2 ± 59.7 µm, P = 0.07). Donor grafts on contact lens had approximately 2.5% more endothelial cells available for transplantation (2425 cells/mm vs. 2367 cells/mm). Graft preparation time did not significantly differ between the methods (6.4 ± 0.49 vs. 9.8 ± 3.7 minutes, P = 0.46).

CONCLUSIONS:

Punching DMEK grafts onto a contact lens reduces endothelial loss at the grafts' margins and may prolong their survival.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Endotelio Corneal / Agudeza Visual / Distrofia Endotelial de Fuchs / Lentes de Contacto / Queratoplastia Endotelial de la Lámina Limitante Posterior / Rechazo de Injerto Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Cornea Año: 2020 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Endotelio Corneal / Agudeza Visual / Distrofia Endotelial de Fuchs / Lentes de Contacto / Queratoplastia Endotelial de la Lámina Limitante Posterior / Rechazo de Injerto Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Cornea Año: 2020 Tipo del documento: Article País de afiliación: Israel