Your browser doesn't support javascript.
loading
Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption.
Wang, Canbin; Chen, Yuhui; Wang, Liping; Wang, Di; Gu, Cheng; Lin, Xuezhi; Liu, Han; Chen, Jiahui; Wen, Xiangyuan; Liu, Yuancheng; Huang, Fuming; Yao, Lufeng; Fan, Shicai; Huang, Wenhua; Dong, Jianghui.
Afiliación
  • Wang C; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Chen Y; The First People's Hospital of Foshan, Foshan, 528200, China.
  • Wang L; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Wang D; Department of Hand Surgery, and Department of Plastic Reconstructive Surgery, Ningbo No. 6 Hospital, Ningbo, 315040, China.
  • Gu C; UniSA Clinical & Health Sciences, and UniSA Cancer Research Institute, University of South Australia, Adelaide, SA, 5001, Australia.
  • Lin X; School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510640, China.
  • Liu H; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Chen J; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Wen X; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Liu Y; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Huang F; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Yao L; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Fan S; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China.
  • Huang W; Department of Hand Surgery, and Department of Plastic Reconstructive Surgery, Ningbo No. 6 Hospital, Ningbo, 315040, China.
  • Dong J; The Third Affiliated Hospital of Southern Medical University, 183 Zhongshan Dadao West Street, Guangzhou, 510600, Guangdong, China. fanscyi@sohu.com.
BMC Musculoskelet Disord ; 21(1): 451, 2020 Jul 10.
Article en En | MEDLINE | ID: mdl-32650750
ABSTRACT

BACKGROUND:

Complicated acetabular fractures comprise the most challenging field for orthopedists. The purpose of this study was to develop three-dimensional printed patient-specific (3DPPS) Ti-6Al-4 V plates to treat complicated acetabular fractures involving quadrilateral plate (QLP) disruption and to evaluate their efficacy.

METHODS:

Fifty patients with acetabular fractures involving QLP disruption were selected between January 2016 and June 2017. Patients were divided into a control group (Group A, 35 patients) and an experimental group (Group B, 15 patients), and were treated by the conventional method of shaping reconstruction plates or with 3DPPS Ti-6AL-4 V plates, respectively. The efficacy of Ti-6AL-4 V plates was evaluated by blood loss, operative time, reduction quality, postoperative residual displacement, and complications.

RESULTS:

The operative time and blood loss in Group B were reduced compared to Group A, and the difference was statistically significant (P < 0.05). There was no significant difference in reduction quality between the two groups (P > 0.05). Reduction quality in Group B was anatomic in 10 (66.7%), satisfactory in four (26.7%), and poor in one (6.7%). In Group A, they were anatomic in 18 (51.4%), satisfactory in 13 (37.1%), and poor in four (11.4%). Residual displacement in Group B was less than that in Group A, and the difference was statistically significant (P < 0.05). In Group B, one case exhibited loosening of the pubic screw postoperatively. In Group A, there was one case of wound infection, one of deep vein thrombosis (DVT) in the ipsilateral lower limb, one case of traumatic arthritis and two obturator nerve injuries.

CONCLUSIONS:

The 3DPPS Ti-6AL-4 V plate is a feasible, accurate and effective implant for acetabular fracture treatment.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas Óseas / Fracturas de Cadera Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas Óseas / Fracturas de Cadera Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2020 Tipo del documento: Article País de afiliación: China