Your browser doesn't support javascript.
loading
A deep learning methodology for the automated detection of end-diastolic frames in intravascular ultrasound images.
Bajaj, Retesh; Huang, Xingru; Kilic, Yakup; Jain, Ajay; Ramasamy, Anantharaman; Torii, Ryo; Moon, James; Koh, Tat; Crake, Tom; Parker, Maurizio K; Tufaro, Vincenzo; Serruys, Patrick W; Pugliese, Francesca; Mathur, Anthony; Baumbach, Andreas; Dijkstra, Jouke; Zhang, Qianni; Bourantas, Christos V.
Afiliación
  • Bajaj R; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Huang X; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK.
  • Kilic Y; School of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK.
  • Jain A; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Ramasamy A; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Torii R; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Moon J; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK.
  • Koh T; Department of Mechanical Engineering, University College London, London, UK.
  • Crake T; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Parker MK; Institute of Cardiovascular Sciences, University College London, London, UK.
  • Tufaro V; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Serruys PW; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Pugliese F; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK.
  • Mathur A; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Baumbach A; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK.
  • Dijkstra J; Faculty of Medicine, National Heart & Lung Institute, Imperial College London, London, UK.
  • Zhang Q; Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Bourantas CV; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK.
Int J Cardiovasc Imaging ; 37(6): 1825-1837, 2021 Jun.
Article en En | MEDLINE | ID: mdl-33590430
ABSTRACT
Coronary luminal dimensions change during the cardiac cycle. However, contemporary volumetric intravascular ultrasound (IVUS) analysis is performed in non-gated images as existing methods to acquire gated or to retrospectively gate IVUS images have failed to dominate in research. We developed a novel deep learning (DL)-methodology for end-diastolic frame detection in IVUS and compared its efficacy against expert analysts and a previously established methodology using electrocardiographic (ECG)-estimations as reference standard. Near-infrared spectroscopy-IVUS (NIRS-IVUS) data were prospectively acquired from 20 coronary arteries and co-registered with the concurrent ECG-signal to identify end-diastolic frames. A DL-methodology which takes advantage of changes in intensity of corresponding pixels in consecutive NIRS-IVUS frames and consists of a network model designed in a bidirectional gated-recurrent-unit (Bi-GRU) structure was trained to detect end-diastolic frames. The efficacy of the DL-methodology in identifying end-diastolic frames was compared with two expert analysts and a conventional image-based (CIB)-methodology that relies on detecting vessel movement to estimate phases of the cardiac cycle. A window of ± 100 ms from the ECG estimations was used to define accurate end-diastolic frames detection. The ECG-signal identified 3,167 end-diastolic frames. The mean difference between DL and ECG estimations was 3 ± 112 ms while the mean differences between the 1st-analyst and ECG, 2nd-analyst and ECG and CIB-methodology and ECG were 86 ± 192 ms, 78 ± 183 ms and 59 ± 207 ms, respectively. The DL-methodology was able to accurately detect 80.4%, while the two analysts and the CIB-methodology detected 39.0%, 43.4% and 42.8% of end-diastolic frames, respectively (P < 0.05). The DL-methodology can identify NIRS-IVUS end-diastolic frames accurately and should be preferred over expert analysts and CIB-methodologies, which have limited efficacy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aprendizaje Profundo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aprendizaje Profundo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Reino Unido