Your browser doesn't support javascript.
loading
Relative and absolute reliability of somatosensory evoked potentials in response to non-noxious electrical stimulation of the paraspinal muscles in healthy participants at an interval of 3-months.
Cunningham, Chelsea N; Jenkins, Luke C; Chang, Wei-Ju; McAuley, James H; Schabrun, Siobhan M.
Afiliación
  • Cunningham CN; Centre for Pain IMPACT, Neuroscience Research Australia, Randwick, NSW, Australia.
  • Jenkins LC; Centre for Pain IMPACT, Neuroscience Research Australia, Randwick, NSW, Australia.
  • Chang WJ; School of Science and Health, Western Sydney University, Penrith, NSW, Australia.
  • McAuley JH; Centre for Pain IMPACT, Neuroscience Research Australia, Randwick, NSW, Australia.
  • Schabrun SM; Centre for Pain IMPACT, Neuroscience Research Australia, Randwick, NSW, Australia.
Int J Neurosci ; 133(1): 103-109, 2023 Jan.
Article en En | MEDLINE | ID: mdl-33663320
ABSTRACT

BACKGROUND:

Somatosensory evoked potentials (SEPs) are used extensively to quantify cortical activity in response to noxious and/or non-noxious sensory stimuli. However, data demonstrating the reliability of SEP measures in response to non-noxious stimulation over time are scarce.

AIM:

We investigated the relative and absolute reliability, and the smallest detectable change at 95% confidence (SDC95) for SEPs evoked by non-noxious electrical stimulation of the paraspinal muscles in thirty-nine healthy participants at a 3-month interval.

METHODS:

SEPs were evoked at an intensity three-times that of each participant's perceptual threshold and recorded from a single electrode placed over the primary somatosensory cortex (S1).

RESULTS:

Our analyses reveal that i) latency, as a measure of activity onset, has poor relative reliability but good absolute reliability; ii) area, as a measure of cortical activity, has good relative and absolute reliability (except for the N150 component) and iii) perceptual threshold and stimulation intensity was not reliable over time.

CONCLUSION:

These findings suggest that the area of the N80 and P260 SEP components, and the area of the N80-N150-P260 SEP complex, can be utilised in future studies as reliable markers of cortical activity.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Potenciales Evocados Somatosensoriales / Músculos Paraespinales Límite: Humans Idioma: En Revista: Int J Neurosci Año: 2023 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Potenciales Evocados Somatosensoriales / Músculos Paraespinales Límite: Humans Idioma: En Revista: Int J Neurosci Año: 2023 Tipo del documento: Article País de afiliación: Australia