Your browser doesn't support javascript.
loading
Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo ("TrueFISP") phase-sensitive inversion recovery.
Xie, L J; Xu, R; Xu, Z Y; Li, X S; Zhou, X Y; Bi, X M; Mu, J S; Fan, H M; Xu, H Y; Guo, Y K.
Afiliación
  • Xie LJ; Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Paediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, 20# South Renmin Road, Chengdu, Sichuan, 610041, China.
  • Xu R; Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Paediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, 20# South Renmin Road, Chengdu, Sichuan, 610041, China.
  • Xu ZY; Department of Radiology, The First Medical Center of Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Li XS; Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Paediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, 20# South Renmin Road, Chengdu, Sichuan, 610041, China.
  • Zhou XY; MR Collaboration, Siemens Healthineers, Shanghai, China.
  • Bi XM; Siemens Medical Solutions USA, Los Angeles, USA.
  • Mu JS; Clinical Application Specialist, Circle Cardiovascular Imaging, Calgary, Canada.
  • Fan HM; Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, Xi'an, 710069, China. Electronic address: fanhm@nwu.edu.cn.
  • Xu HY; Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Paediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, 20# South Renmin Road, Chengdu, Sichuan, 610041, China. Electronic address: xuhuayan89@sina.com.
  • Guo YK; Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Paediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, 20# South Renmin Road, Chengdu, Sichuan, 610041, China. Electronic address: gykpanda@163.com.
Clin Radiol ; 76(6): 471.e17-471.e25, 2021 Jun.
Article en En | MEDLINE | ID: mdl-33663913
ABSTRACT

AIM:

To investigate the value of motion-corrected (MOCO) phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) compared with single-shot balanced steady-state gradient echo ("TrueFISP", Siemens) PSIR in free breathing paediatric patients. MATERIALS AND

METHODS:

In this retrospective study, 238 paediatric patients underwent clinical contrast-enhanced cardiovascular magnetic resonance imaging (CMRI). Both the single-shot TrueFISP PSIR and MOCO PSIR sequences were performed on each child. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists rated the quality of the images on a scale of 1-5 (1 = poor, 5 = very good). Bland-Altman, linear regression, and intraclass correlation coefficient were used to compared the extent of LGE of the single-shot TrueFISP PSIR and MOCO PSIR. Imaging artefacts were described and compared.

RESULTS:

Children ranged in age from 60 days to 17 years with an average age of 8.1 ± 3.8 years. MOCO PSIR had higher SNR and CNR than the single-shot TrueFISP PSIR (p<0.001). Mean quality ratings for short-axis imaging were 4 (interquartile range, 3-4) for single-shot TrueFISP PSIR and 4 (interquartile range, 4-5) for MOCO PSIR (p<0.001). The scan time was faster for single-shot TrueFISP PSIR than for MOCO PSIR. The myocardial LGE results were similar with high agreement between the single-shot TrueFISP PSIR and MOCO PSIR (ICC = 0.955-0.986).

CONCLUSION:

The MOCO PSIR sequence is feasible in children. MOCO PSIR is robust at high heart rates and can be performed without breath-holding with higher image-quality ratings than the single-shot TrueFISP PSIR.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Medios de Contraste / Gadolinio / Cardiopatías Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Clin Radiol Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Medios de Contraste / Gadolinio / Cardiopatías Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Clin Radiol Año: 2021 Tipo del documento: Article País de afiliación: China