Your browser doesn't support javascript.
loading
Femoral arterial cannulation remains a safe and reliable option for aortic dissection repair.
Lemaire, Anthony; Chao, Joshua; Salgueiro, Lauren; Ikegami, Hirohisa; Lee, Leonard Y.
Afiliación
  • Lemaire A; Rutgers Robert Wood Johnson Medical Center, New Brunswick, USA.
  • Chao J; Rutgers Robert Wood Johnson Medical Center, New Brunswick, USA.
  • Salgueiro L; Rutgers Robert Wood Johnson Medical Center, New Brunswick, USA.
  • Ikegami H; Rutgers Robert Wood Johnson Medical Center, New Brunswick, USA.
  • Lee LY; Rutgers Robert Wood Johnson Medical Center, New Brunswick, USA.
J Thorac Dis ; 13(2): 1005-1010, 2021 Feb.
Article en En | MEDLINE | ID: mdl-33717573
BACKGROUND: The optimal cannulation site for repair of type A aortic dissection remains controversial. The concern for Malperfusion syndrome has initiated a national trend away from femoral cannulation to axillary artery and direct ascending aortic cannulation. The purpose of this study was to report a single center experience with femoral artery cannulation for the repair of a type A dissection. METHODS: A retrospective study was performed on 52 patients who underwent surgical repair for a type A dissection between January 1st, 2012 and June 30th, 2019 at a single institution. Of the 52 patients analyzed, 35 (67.3%) underwent femoral artery, 11 (21.2%) direct ascending aortic, and 6 (11%) axillary artery cannulation for arterial access. Deep hypothermic circulatory arrest was used in all the patients. Rates of postoperative complication and mortality were reported. RESULTS: The mortality and bleeding rates for all the patients undergoing repair of the type A dissection repairs were 27% (14/52) and 19% (10/52), respectively. Cardiopulmonary bypass was established in 100% of the patients that had femoral arterial cannulation. There were no complications specifically related to femoral arterial cannulation nor the axillary or direct aortic approach. Specifically, there was no episodes of malperfusion syndrome, bleeding, or injury with femoral artery cannulation. Bleeding rates were higher in cases that proceeded with a femoral (13%) versus alternate (6%) approach however; neither of the bleeding was related to the cannulation site. None of the mortalities identified were directly attributable to the cannulation approach in each case. CONCLUSIONS: Despite the recent shift away from femoral cannulation, the results of the study show that femoral artery cannulation is safe and produces excellent results for establishing cardiopulmonary bypass. The concerns for malperfusion syndrome related to femoral cannulation were not seen.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Revista: J Thorac Dis Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Revista: J Thorac Dis Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos