Your browser doesn't support javascript.
loading
A novel fast-dried urine spot-based method for the analysis of EtS and EtG in urine by liquid chromatography tandem mass spectrometry.
Wang, Hao; Zhang, Yunfeng; Fan, Enshan; Wang, Fangling; Li, Beixu; Rao, Yulan.
Afiliación
  • Wang H; Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, PR China.
  • Zhang Y; Institute of Forensic Science, Ministry of Public Security, Beijing 100038, PR China.
  • Fan E; Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, PR China.
  • Wang F; Institute of Forensic Science, Ministry of Public Security, Beijing 100038, PR China.
  • Li B; School of Policing Studies, Shanghai University of Political Science and Law, Shanghai 201701, PR China. Electronic address: libeixu@shupl.edu.cn.
  • Rao Y; Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, PR China. Electronic address: yulan_rao@fudan.edu.cn.
Article en En | MEDLINE | ID: mdl-33744600
Ethyl sulfate (EtS) and ethyl glucuronide (EtG) in urine are biomarkers to monitor ethanol consumption. Due to their high polarity, severe matrix effects have been observed during analysis of EtS and EtG in urine by liquid chromatography tandem mass spectrometry (LC-MS/MS), which can lead to a loss of sensitivity and accuracy. In the present study, a novel and simple sample preparation approach based on fast-dried urine spot was established to reduce the matrix effect of EtS and EtG in urine. 20 µL of urine was dropped on the Whatman 903# paper and was subsequently dried by microwave in one minute. After ultrasonic assisted extraction with 500 µL of methanol, the analysis was conducted using an LC-MS/MS system. Limits of detection were 5 ng/mL and linear ranges were 10 ng/mL-10 µg/mL for both EtS and EtG. Matrix effects were in the range of 99.3-107.8% for EtS and 86.7-91.0% for EtG at three QC levels. Matrix effects for EtS and EtG were compared between the current method and other sample preparation methods including protein precipitation, and solid-phase extraction. The results showed that this fast-dried urine spot-based extraction method could eliminate matrix effects significantly in analysis of urine EtS and EtG by LC-MS/MS.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ésteres del Ácido Sulfúrico / Cromatografía Liquida / Espectrometría de Masas en Tándem / Glucuronatos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ésteres del Ácido Sulfúrico / Cromatografía Liquida / Espectrometría de Masas en Tándem / Glucuronatos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article