Your browser doesn't support javascript.
loading
Automated and Faster Affinity Capture Method for Biotransformation Assessment of Site-Specific Antibody Drug Conjugates.
Jashnani, Aarti; Kotapati, Srikanth; Deshpande, Madhura; Yamazoe, Sayumi; Strop, Pavel; Rajpal, Arvind; Dollinger, Gavin.
Afiliación
  • Jashnani A; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Kotapati S; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Deshpande M; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Yamazoe S; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Strop P; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Rajpal A; Discovery Biotherapeutics, Bristol-Myers Squibb, 700 Bay Road, Redwood City, California 94063, United States.
  • Dollinger G; Large Molecule Drug Discovery, Genentech, Inc., 1 DNA Way, South San Francisco, California 94080, United States.
Anal Chem ; 93(13): 5371-5376, 2021 04 06.
Article en En | MEDLINE | ID: mdl-33750099
Traditionally the biotransformation of antibody drug conjugates (ADCs) has been evaluated by affinity capture on streptavidin magnetic beads coated with a biotinylated capture reagent. To reduce the complexity of the analyte, the affinity captured ADCs are digested with enzymes ("on-bead" or after elution), and/or interchain disulfides are reduced to generate LC and HC fragments prior to mass spectrometry analysis. The "on-bead" enzymatic digestion with IdeS and PNGase F is not efficient and requires longer incubation times to achieve complete Fc and N-glycan removal. This results in a prolonged sample preparation time (7-18 h) and is not suitable for labile ADCs due to the possibility of assay-induced artifacts. To address these challenges, we developed an affinity capture method, where the ADCs are first captured onto streptavidin cartridges coated with a biotinylated generic capture reagent, followed by a 15 min "on-cartridge" digestion with IdeS or PNGase F. The ADCs are then eluted and directly analyzed by LC-HRMS. This method was successfully applied for the biotransformation assessment of site-specific ADCs with payload conjugated on the Fab or Fc. The reduced complexity of the analyte (Fc and N-glycan removal) combined with HRMS enabled sensitive and accurate identification of minor mass change catabolites and changes in the DAR distribution. This automated cartridge-based affinity capture method is fast with a total sample preparation time of less than 4 h (hands-on time of less than 1 h) and can be utilized for any human mAb/ADC independent of isotype (IgG1, IgG2, and IgG4).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Inmunoconjugados Límite: Humans Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Inmunoconjugados Límite: Humans Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos